8
18
-15.
100
b-GB
.f
m
9.10
Press and hold the RESET key.
9.11
Press the
OFF key within 2 s.
• The LED in the sensor of the fitting flashes:
9.12
Press the
OFF key within 10 s.
• The LED in the sensor of the fitting flashes:
– 4 x short: The "Hygiene flushing" function is switched on.
– 2 × long: The "Hygiene flushing" function is switched off.
9.13
Wait 10 s.
• The system exits from the setting mode.
Setting the Flushing Interval
9.14
Press the TEST key.
9.15
Press the
ON key repeatedly until the required mode has been set.
• The LED in the sensor of the fitting flashes:
9.16
Exit the adjustment mode.
• Press the TEST key.
or wait
• 60 s.
Setting the flushing duration – Protronic-C
The flushing duration can be set at one minute intervals from 1 to 10 minutes.
☞
The flushing duration is factory-set to 5 minutes.
9.17
Press the TEST key.
9.18
Use the + and – (
) keys to adjust the flushing duration in individual steps.
• The LED in the sensor of the fitting flashes:
– 4 × short = adjustment by one stage (approx. 1 minute).
– 2 × long = end setting reached
9.19
Exit the adjustment mode.
• Press the TEST key.
or wait
• 60 s.
Protronic-C
Protronic-S
– 2 × long = 1 day
– 1 × short = 8 h
– 4 × short = 3 days
– 2 × short = 24 h
– 3 × short = 36 h
– 4 × short = 72 h
☞
The flushing interval is
factory-set to 3 days.
☞
The flushing interval is
factory-set to 24 h.