Activating continual flow (thermal disinfection)

9.4

Turn the mixing lever of the fitting to the hot water limit stop (see instructions for the 
fitting). 

9.5

Press the 

ON key.

• Continual flow is started (solenoid valve opens).

Continuous flow can be prematurely terminated by pressing the 

ON key again.

Setting the automatic safety shut-off.

When an object is continually detected for 60 s, the water flow stops automatically.

9.6

Press and hold the RESET key.

9.7

Press the 

OFF key within 2 s. 

• The LED in the sensor of the fitting flashes.

9.8

Use the + and – (

) keys to adjust the switch-off time in individual steps.

• The LED in the sensor of the fitting flashes:

– 4 × short for each adjustment up to 60 s by one step (5 s)
– 8 × short for each adjustment from 60 s by one step (60 s)
– 2 x long when the respective end setting is reached

9.9

Wait 10 s.

• The system exits from the setting mode.

Activating/deactivating Hygiene flushing

The "Hygiene flushing" function ensures water hygiene when the fitting is not used 
for a prolonged period. The water flow is activated for 1-10 minutes after 1 or 3 days 
of non-use.

Caution!

• When the “Hygiene Flushing” function is used, it must be ensured that the water 

can flow away properly.

• When the "Hygiene flushing" function is to be used for both the hot and cold water 

lines, the mixer lever of the fitting should be in the mixed-water position.

This function is not available for products manufactured before 1 May, 2002. When 
the respective keys are pressed, the LED in the sensor of the fitting does not flash.

Important!

Protronic-C: When the "Hygiene flushing" function is active, this state is indicated by 
an LED within 3 minutes after the voltage supply is interrupted and reconnected for 
object detection.

The factory default setting for "Hygiene Flushing" is deactivated.

Содержание ZAQUA091

Страница 1: ...n and operating instructions Montage en bedrijfsinstructies Notice de montage et de mise en service Monta i instrukcja obs ugi Istruzioni per il montaggio e l uso Franke Aquarotter GmbH EA Nr 76129821...

Страница 2: ...graphiques sont disponibles dans la notice de montage et de mise en service allemande 25 Per le grafiche fare riferimento alle Istruzioni per il montaggio e l uso in tedesco 36 De tekeningen kunt u i...

Страница 3: ...for Remote Control 4 8 Functions 5 9 Wash Fitting Settings 6 10 Urinal Settings 11 11 Additional Settings for the Urinal 12 Maintenance 12 Changing the Battery 13 1 Warranty Liability is accepted acco...

Страница 4: ...remote control flashes twice slowly Protronic S The LED in the remote control flashes 4 times slowly 7 Activating the Fitting for Remote Control Perform the following with the remote activation befor...

Страница 5: ...e sensor range can be tested and adjusted without flowing water in test mode 8 1 Press the TEST key Test mode is activated The LED in the sensor of the fitting flashes 4 short break 4 short The LED in...

Страница 6: ...eak 3 short break 8 7 Press the OFF key again The fitting is ready for operation 9 Wash Fitting Settings Setting for continual flow A time of 3 5 min or 11 min can be set for continual flow preset 3 5...

Страница 7: ...pective end setting is reached 9 9 Wait 10 s The system exits from the setting mode Activating deactivating Hygiene flushing The Hygiene flushing function ensures water hygiene when the fitting is not...

Страница 8: ...e fitting flashes 9 16 Exit the adjustment mode Press the TEST key or wait 60 s Setting the flushing duration Protronic C The flushing duration can be set at one minute intervals from 1 to 10 minutes...

Страница 9: ...21 Use the and keys to adjust the flushing duration in individual steps The LED in the sensor of the fitting flashes 4 short Adjust by one step 2 long End setting reached 9 22 Exit the adjustment mod...

Страница 10: ...ensor range can be adjusted see Chapter 8 The LED in the sensor of the fitting flashes 5 long 3 short The water flow should start stop when a person approaches moves away from the sensor 35 cm 9 26 Pr...

Страница 11: ...t 10 s The system exits from the setting mode Resetting default factory settings Reset 10 5 Press the RESET key for at least 3 s The system now has the factory settings again The LED in the sensor of...

Страница 12: ...lushing on off Intermediate flushing is factory set to ON 11 4 Press and hold the TEST key 11 5 Press the OFF key within 2 s The LED in the sensor of the fitting flashes 4 x short Intermediate flushin...

Страница 13: ...ontrol 12 2 Remove the cover b 12 3 Remove the batteries c 12 4 Check and clean the contacts Replace the batteries if required Use Micro 1 5V AAA LR03 type batteries and ensure correct polarity 12 5 R...

Отзывы: