5
18
-15.
100
b-GB
.f
m
7.2
When a remote command is accepted, the LED in the sensor (d) of the fitting
flashes. The flashing intervals are described in the relevant functional description.
• Each time that a remote command is accepted, the fitting remains in remote
control mode for a further 60 s.
• This does not apply for cleaning switch-off.
☞
A flashing LED in the sensor (d) of the fitting is only visible at sensor height for the
Protronic-S series of products.
8. Functions
Test mode = Simulation without water
The sensor range can be tested and adjusted without flowing water in test mode.
8.1
Press the TEST key.
• Test mode is activated.
• The LED in the sensor of the fitting flashes:
– 4 × short, break, 4 × short
• The LED in the sensor of the fitting lights up when a hand or object is detected.
8.2
Set the sensor range.
8.3
Exit the adjustment mode.
• Press the TEST key.
or wait
• 60 s.
• The LED in the sensor of the fitting flashes:
– 4 × short, break, 4 × short
• The LED in the sensor of the fitting is off.
Setting the sensor range
8.4
Use the + and – (
) keys to adjust the sensor range in individual steps.
• The LED in the sensor of the fitting flashes:
– 4 × short for each adjustment by one step
– 2 x long when the respective end setting is reached