ULPP Configuration
512
wait for some times before the master port preempt the slave port. For keeping the
continuance of the flows, the master port does not process to preempt by default, but
turns into the Standby state.
When configuring ULPP, it needs to specify the VLAN which is protected by this
ULPP group through the method of MSTP instances, and ULPP does not provide the
protection to other VLANs.
When the uplink switch is happennig, the primary forwarding entries of the device will
not be applied to new topology in the network. In the figure, SwitchA configures ULPP, the
portA1 as the master port at forwarding state, here the MAC address of PC is learned by
Switch D from portD3. After this, portA1 has the problem, the traffic is switched to portA2
to be forwarded. If there is the data sent to PC by SwitchD, still the data will be forwarded
from portD3, and will be losed. Therefore, when switching the uplink, the device of
configuring ULPP needs to send the flush packets through the port which is switched to
Forwarding state, and update MAC address tables and ARP tables of other devices in the
network. ULPP respectively uses two kinds of flush packets to update the entries: the
updated packets of MAC address and the deleted packets of ARP.
For making use of the bandwidth resource enough, ULPP can implement VLAN load
balance through the configuration. As the picture illustrated, SwitchA configures two ULPP
groups: portA1 is the master port and portA2 is the slave port in group1, portA2 is the
master port and portA1 is the slave port in group2, the VLANs are protected by group1
and group2, they are 1-100 and 101-200. Here both portA1 and portA2 at the forwarding
state, the master port and the slave port mutually backup, and respectively forward the
packets of the different VLAN ranges. When portA1 has the problem, the traffic of VLAN
1-200 are forwarded by portA2. After this, when portA1 is recovering the normal state,
portA2 forwards the data of VLAN 101-200 sequentially, but the data of VLAN 1-100 is
switched to portA1 to forward.