FOR-A USF-212PS Скачать руководство пользователя страница 40

 

 
 
 
 
 
 
 
 
 

FOR-A COMPANY LIMITED 

Head Office 

 

3-8-1 Ebisu, Shibuya-ku, Tokyo 150-0013, Japan 

Overseas Division 

Tel: +81(0)3 3446 3936 

Fax: +81(0)3 3446 1470 

Japan Branch Offices  

Osaka/Okinawa/Fukuoka/Hiroshima/Nagoya/Sendai/Sapporo 

R&D/Production    

Sakura Center/Sapporo Center 

FOR-A Corporation of America 

11155 Knott Ave., Suite G&H, Cypress, CA 90630, USA. 
Tel: +1 714 894 3311 

Fax: +1 714 894 5399 

FOR-A Corporation of America East Coast Office 

2 Executive Drive, Suite 670, Fort Lee Executive Park, Fort Lee, NJ 07024, USA 
Tel: +1 201 944 1120 

Fax: +1 201 944 1132 

FOR-A Corporation of America Distribution & Service Center 

2400 N.E. Waldo Road, Gainesville, FL 32609, USA 
Tel: +1 352 371 1505 

Fax: +1 352 378 5320 

FOR-A Corporation of America Miami Office 

8333 North West 53rd Street Suite 427 Doral, FL 33166, USA 
Tel: +1 305 931 1700 

Fax: +1 714 894 5399 

FOR-A Corporation of Canada 

1131A, Leslie Street Suite 209, Toronto, Ontario M3C 2J6, Canada 
Tel: +1 416 977 0343 

Fax: +1 416 977 0657 

FOR-A Europe S.r.l. 

Via Volturno 37, 20861 Brugherio MB, Italy 
Tel: +39 039 91 64 811 

Fax: +39 039 878 140 

FOR A UK Limited 

Trident Court, 1 Oakcroft Road, Chessington, KT9 1BD, UK 
Tel: +44 (0)20 3044 2935   Fax: +44(0)20 3044 2936 

FOR-A Italia S.r.l. 

Via Volturno 37, 20861 Brugherio MB, Italy 
Tel: +39 039 881 086/103  Fax: +39 039 878 140 

FOR-A Corporation of Korea 

1007, 57-5, Yangsan-ro, Yeongdeungpo-gu, Seoul 150-103, Korea 
Tel: +82 (0)2 2637 0761 

Fax: +82 (0)2 2637 0760 

FOR-A China Limited 

708B Huateng Building, No. 302, 3 District, Jinsong, Chaoyang, Beijing 100021, China 
Tel: +86 (0)10 8721 6023 

Fax: +86 (0)10 8721 6033 

FOR-A Middle East-Africa Office 

Dubai Media City, Aurora Tower, Office 1407, P.O. Box 502688, Dubai, UAE 
Tel: +971 (0)4 551 5830 

Fax: +971 (0)4 551 5832 

Agiv (India) Private Limited (FOR-A India) 

2nd Floor, Valecha Chambers, Link Road, Andheri(W), Mumbai 400053 
Tel: +91-22-26733623 

Fax: +91-22-26393415 

 

December 28, 2016   Printed in Japan 

http://www.for-a.com/ 

Содержание USF-212PS

Страница 1: ...USF 212S Universal System Frame USF 212PS Power Supply Unit 2nd Edition OPERATION MANUAL...

Страница 2: ...round the unit to gas lines units or fixtures of an explosive or dangerous nature Operation Hazard Do not operate the unit under hazardous or potentially explosive atmospheric conditions Doing so coul...

Страница 3: ...d disconnect the power cord to avoid potentially hazardous conditions If problems similar to the above occur contact an authorized service representative before attempting to operate the unit again Ra...

Страница 4: ...ved items against the packing lists below Check to ensure no damage has occurred during shipment If damage has occurred or items are missing inform your supplier immediately USF 212S ITEM QTY REMARKS...

Страница 5: ...odule 18 6 Replacing a USF Module 19 6 1 Removing the Front Module 19 6 2 Removing the Rear Module 19 7 Installing or Removing a Power Supply Unit 20 7 1 Installing a Power Supply Unit 20 7 2 Removing...

Страница 6: ...6...

Страница 7: ...nits both support hot swapping Alarm sensors Fan Stop Power Unit Voltage Error Temperature Error and status indicators Power Fan Temperature are shown on front LEDs Alarm data able to output from rear...

Страница 8: ...strap toward the unit 2 Insert the anchor into the hole next to the AC IN socket 3 Lightly fasten the clip around the AC cord 4 Plug in the power cord 5 Slide the clip on the ladder strap toward the p...

Страница 9: ...o Name Description 1 POWER ON This LED lights green when DC power is supplied normally DC 1 This LED lights red when a voltage error occurs in power module 1 DC 2 This LED lights red when a voltage er...

Страница 10: ...NIVERSAL SYSTEM FRAME LOCK LOCK 2 Pull out the front panel using the pull handles The fan stops while the front panel is open TEMP FAN DC2 DC1 ALARM ON POWER USF 212 UNIVERSAL SYSTEM FRAME LOCK LOCK I...

Страница 11: ...ard NOTE Handle the front panel carefully so as not to bend the rails IMPORTANT After the front panel is installed the ALARM LED on the front panel will light in the following order DC1 DC2 FAN TEMP T...

Страница 12: ...terminal LAN1 LAN2 LAN A are available Allows control over the respective modules Allows to supply GENLOCK1 2 to respective slots 4 Expansion slot Not used 5 USF Module Slots Dedicated USF module slo...

Страница 13: ...ing an optional USF 212PS power supply unit When an optional USF 212PS is not installed a blank panel is used to cover the blank power supply unit 2 PS2 slot NOTE Turn on the power supply switch on th...

Страница 14: ...ound terminal Grounds the power supply for safety 4 GENLOCK 1 GENLOCK 2 Inputs genlock signals Black Burst BB or tri level sync The lower connector is for a loop through connection Terminate with 75 i...

Страница 15: ...us The USF 212S frame provides 4 slot groupings internal SDI bus which allows SDI signals to be transferred bi directionally The signal application differs for each module Refer to the operation manua...

Страница 16: ...4 ALARM 4 5 ALARM 5 6 ALARM 6 7 GND GND 8 GND GND 9 GND GND Open collector alarm output ALARM 1 to 6 Maximum current limit 24VDC 50mA 4 10 1 Example of Alarm Connection Example of ALARM1 ALARM2 Open...

Страница 17: ...an be installed and uninstalled while the power is on in case of emergency Shut down the power for non emergency work When installing uninstalling the front module while the power is on the front pane...

Страница 18: ...the guide rail and carefully insert the front module slowly PCB Guide Rail Locations 3 Push the handle until the front module clicks into the connectors IMPORTANT Inserting the module by pressing on...

Страница 19: ...down the power to install and uninstall a control module The procedure for replacing a module in Slot 4 is described below as an example 6 1 Removing the Front Module 1 Open the front panel and shut...

Страница 20: ...front panel immediately after the operation is completed 7 1 Installing a Power Supply Unit The procedure for installing a USF 212PS unit into the PS2 Slot is explained as an example 1 Open the front...

Страница 21: ...ower Supply 1 from the back side Refer to Sec 2 Installing the AC Cord Retaining Clip for details 4 Loosen the screw of the power supply fixing bracket by turning it counterclockwise When the screw is...

Страница 22: ...or LAN A port is forgotten use this setting which allows you to access the USF 212S from the web browser with the factory default IP address of the port LAN1 2 192 168 0 10 LAN A 172 16 0 10 The lost...

Страница 23: ...a PC Connect LAN 1 LAN 2 or LAN A connector to a PC via a hub LAN 1 LAN 2 and LAN A have different functions 9 1 1 Connecting LAN 1 and LAN 2 Ports The installed control modules are connected to the U...

Страница 24: ...Example 9 2 PC System Requirements Web GUI requires the following minimum PC specifications OS Windows 7 8 8 1 operating system Professional 32 64bit CPU Intel Core 2 Duo processor 2GHz or more Memor...

Страница 25: ...SF 212S is displayed on the web browser 10 1 Status Tab Clicking the Status tab opens a window as shown below Clicking Refresh allows you to update the window contents The modules mounted in slots 1 t...

Страница 26: ...tely turn off the power supply and contact your supplier Fan Operation status of Power Unit FAN is indicated Normal Functioning Stopped The fan has stopped Immediately turn off the power supply and co...

Страница 27: ...curs Abnormal DC output from power supply unit 1 or 2 Stopped FAN 1 2 or 3 High temperature Front panel open Power Unit1 2 Alarm Alarm signal output Indicates abnormal DC output from Power Supply unit...

Страница 28: ...GUI accesses to the external LAN A SNMP Base Port 56000 Sets the TCP UDP port number through which the SNMP Manager accesses to the external LAN A Control Base Port 57000 Sets the TCP UDP port number...

Страница 29: ...ccesses to the LAN 1 2 port Subnet Mask and Gateway setting values apply to all modules mounted in slots 1 to 12 IP Address and Gateway should be the same address when utilizing the router function to...

Страница 30: ...tion Base file The MIB file can be downloaded according to the following procedure 1 Click Download MIB File 2 Click Save of FORA USF 212S MIB zip file 3 Unzip the file and load it to SNMP Manager Com...

Страница 31: ...ply Unit 1 failure occurs a Trap command is sent DC Power 1 Trap Enable Disable Enable Enable If DC power supply failure occurs in Power Supply Unit 1 a Trap command is sent PS Unit 2 Trap Enable Disa...

Страница 32: ...ick OK to execute restart Parameter Backup Exports saves as a file and imports loads from a file USF 212S setting parameters Export 1 Click Export to save the settings to a file File name usf 212s csv...

Страница 33: ...encoded CSV Comma Separated Value file without BOM Byte Order Mark Slot Name Any name up to 15 characters can be given to Slots 1 to 12 Half width and Full width characters The set name is displayed...

Страница 34: ...ER Power Unit2 DC Output usf212SPowerUnit2DcStatus 1 notInstalled 0 normal 1 abnormal 9 INTEGER Power Unit2 FAN Status usf212SPowerUnit2FanStatus 1 notInstalled 0 normal 1 stopped 10 INTEGER Card Temp...

Страница 35: ...pply Unit1 Detection Change usf212SPowerUnit1DetectionChanged 1 INTEGER usf212PowerUnit1Detection Power Supply Unit1 DC Output Status Change usf212SPowerUnit1DcStatusChanged 2 INTEGER usf212PowerUnit1...

Страница 36: ...Hz Power Consumption 670VA at 100 to 120V AC at maximum output current 660VA at 220 to 240V AC at maximum output current Dimensions 440 W x 88 H x 401 D mm Weight 10 kg Including 1 unit of power suppl...

Страница 37: ...RAME USF 212 LOCK POW ER ON ALA RM DC1 DC2 FAN TE MP LOCK U SF 21 2 ALAR M L AN A L AN 2 L AN 1 G ENLOC K 2 G ENLOC K 1 AC 1 0 0 2 4 0 V 5 0 60 Hz IN 2 AC10 0 2 40 V 5 0 6 0 Hz IN 1 462 19 50 19 76 6...

Страница 38: ......

Страница 39: ...n the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may...

Страница 40: ...of Canada 1131A Leslie Street Suite 209 Toronto Ontario M3C 2J6 Canada Tel 1 416 977 0343 Fax 1 416 977 0657 FOR A Europe S r l Via Volturno 37 20861 Brugherio MB Italy Tel 39 039 91 64 811 Fax 39 039...

Отзывы: