9. Control via Web GUI
USF-212S operation can be monitored by a web browser or SNMP Manager via a PC-network
connection. Power supply, fan, and temperature states can be displayed by opening the USF-212S
Web GUI from a web browser. Control and monitoring of the modules (*1) installed in USF-212S can be
done via Web GUI. ALARM function assignments of the rear ALARM connector can be set via Web GUI.
It is also possible to monitor power supply, fan, temperature, modules (1*) through an SNMP manager.
(*1)Possible for the network support modules only. Refer to the operation manual of respective
modules.
9-1. Connecting USF-212S to a PC
Connect LAN 1, LAN 2 or LAN A connector to a PC via a hub.
LAN 1, LAN 2 and LAN A have different functions.
9-1-1. Connecting LAN 1 and LAN 2 Ports
The installed control modules are connected to the USF-212S internal switching hub. The LAN
1 and LAN 2 ports on the rear panel are also connected to the USF-212S internal switching
hub. This requires different IP addresses to be set for these ports and other devices in this
network. When a large amount of data is to be exchanged per module, use the LAN 1 or LAN
2 port.
Factory settings
LAN 1 and LAN 2 IP address: 192.168.0.10
Refer to LAN 1 and LAN 2 settings of Sec. 10-3
. "Network Tab” for details on changing network
settings.
Connection Example
LAN1
LED
(LAN2
LED)
Lit Green
: Connected
Flashing Orange:
Transmitting
and receiving data
USF-212S Rear
Web Browser
SNMP Manager