8. Control Module
Make sure to shut down the power when replacing the control module.
8-1. Internal Control Module Settings
Remove the module by loosening the screw on front and pulling the module out using the grab
handle.
Name
Descriptions
Switch S2
CPU reset switch. Not used normally.
Switch S3
Reset switch for the built-in hub. Not used normally.
Micro SD CARD Connector
For maintenance purposes only.
Do not connect Micro SD CARD.
DS1 Settings
No.
Factory Setting
Description
1
Off
Off: Front Panel Open warning alarm is enabled.
On: Front Panel Open warning alarm is disabled.
2
Off
Off: Normal use.
On: The USF-212S operates at the default network settings.
If the IP address of the LAN1/2 or LAN A port is forgotten, use
this setting, which allows you to access the USF-212S from the
web browser with the factory default IP address of the port.
(LAN1/2: 192.168.0.10, LAN A: 172.16.0.10) The lost network
configuration is displayed on network tab of the web page. (*1)
3
Off
Off: Do not change the setting.
4
Off
Off: Do not change the setting.
5
Off
Off: Do not change the setting.
6
Off
Off: Do not change the setting.
7
Off
Off
: Do not change the setting.
8
Off
Off: Do not change the setting.
*1 When DS1-2 is turned on, IP addresses of Slot 1 to 12 also returns to default
(192.168.0.11 to 22).
IMPORTANT
If SW2 is turned ON while the network cable is connected, IP addresses are set as default
(LAN1/2: 192.168.0.10 to 22, LAN A: 172.160.0.10). Proceed after confirming these IP
addresses do not conflict with the IP addresses of other devices in the network.
S2
S3
DS1
8
ON
1
Handle
Micro SD connector