35
Power Unit 2 DC
Output
Obtains the Power Unit 2 DC status.
normal: Indicates Power Unit 2 DC output is normal.
abnormal: Indicates Power Unit 2 DC output is abnormal.
notInstalled: Indicates Power Unit 2 is not installed when turned on.
Power Unit 2 FAN
Status
Obtains the Power Unit 2 FAN status.
normal: Indicates the FAN DC output is normal.
stopped: Indicates the FAN DC output is abnormal.
notInstalled: Indicates Power Unit 2 is not installed when turned on.
Card Temperature
Obtains the Control Module temperature status.
Front FAN Status
Obtains the USF-212S Front fan status as Bit0 to Bit2. Bit0 to Bit2 indicate
FAN1 to FAN3 states respectively. Each bit indicates 0 when the fan is
operating, and indicates 1 when the fan has stopped.
Object group
Item Name
Object name in MIB file
Value
OID
Type
TRAP
Function
Note
OID : 1.3.6.1.4.1.20175.1.310.1.13.1.
Module
Information
Slot number inserted
usf212SSlotNumber
1 to 12
1. a
INTEGER
Slot inserted status
usf212SSlotStatus
0:moduleIn
1:noModule
2. a
INTEGER
Slot installed module
name
usf212SSlotModuleName **********
3. a
OCTET
STRING
* Letter "a" represents slot number 1 to 12.
* Module
TRAP List
Object
group
Item Name
Object name in MIB file
OID
Type
Reference Object
TRAP
Power Supply Unit1
Detection Change
usf212SPowerUnit1DetectionChanged
1
INTEGER usf212PowerUnit1Detection
Power Supply Unit1 DC
Output Status Change
usf212SPowerUnit1DcStatusChanged
2
INTEGER usf212PowerUnit1DcStatus
Power Supply Unit1 FAN
Status Change
usf212SPowerUnit1FanStatusChanged
3
INTEGER usf212PowerUnit1FanStatus
Power Supply Unit2
Detection Change
usf212SPowerUnit2DetectionChanged
4
INTEGER usf212PowerUnit2Detection
Power Supply Unit2 DC
Output Status Change
usf212SPowerUnit2DcStatusChanged
5
INTEGER usf212PowerUnit2DcStatus
Power Supply Unit2 FAN
Status Change
usf212SPowerUnit2FanStatusChanged
6
INTEGER usf212PowerUnit2FanStatus
Front FAN Status Change usf212SFrontFanStatusChanged
8
INTEGER
usf212SFrontFanStatus
Module Status Change
usf212SSlotStatusChanged
11 INTEGER
usf212SSlotNumber
usf212SSlotStatus
Power Supply Unit1
Detection Change
Trap command transmitted when the usf212PowerUnit1Detection
changes.
Power Supply Unit1 Status
Change
Trap command transmitted when the usf212PowerUnit1DcStatus
changes.
Power Supply Unit2
Detection Change
Trap command transmitted when the usf212PowerUnit2Detection
changes.
Power Supply Unit2 Status
Change
Trap command transmitted when the usf212PowerUnit2DcStatus
changes.
Front FAN Status Change
Trap command transmitted when the usf212SFrontFanStatus changes.
Module Status Change
Trap command transmitted when a slot module communication status
changes.