34
11. About SNMP
The USF-212S can be remotely monitored using an SNMP monitoring system that supports SNMPv2C.
Since functions between the USF-212 and USF-212S are different, refer to the SNMP function
descriptions of the unit you are using.
MIB (Management Information Base) files required for SNMP monitoring system can be downloaded
from Web GUI. Refer to Sec. 10-3. "Network Tab" for details on downloading MIB files and SNMP
settings.
GET List
Object
group
Item Name
Object name in MIB file
Value
OID
Type
TRAP
Function
OID: 1.3.6.1.4.1.20175.1.310.1.
Unit Status
Product Name
usf212SProductName
USF-212S
1
OCTET
STRING
Product Code
usf212SProductCode
1023809
2
INTEGER
Serial Number
usf212SerialNumber
1596****
3
INTEGER
Soft Ver
usf212SVersion
**.**
4
OCTET
STRING
Power Unit1
Detection
usf212SPowerUnit1Detection
-1:notInstalled
0:notDetected
1:detected
5
INTEGER
Power Unit1 DC
Output
usf212SPowerUnit1DcStatus
-1:notInstalled 0:normal
1:abnormal
6
INTEGER
Power Unit1 FAN
Status
usf212SPowerUnit1FanStatus
-1:notInstalled
0:normal
1:stopped
7
INTEGER
Power Unit2
Detection
usf212SPowerUnit2Detection
-1:notInstalled
0:notDetected
1:detected
8
INTEGER
Power Unit2 DC
Output
usf212SPowerUnit2DcStatus
-1:notInstalled
0:normal
1:abnormal
9
INTEGER
Power Unit2 FAN
Status
usf212SPowerUnit2FanStatus
-1:notInstalled
0:normal
1:stopped
10
INTEGER
Card Temperature
usf212SCardTemperature
**degree Celsius
11
INTEGER
Front FAN Status
usf212SFrontFanStatus
0:normal
1:stopped
fan1 Stopped (Bit0) fan2
Stopped (Bit1) fan3
Stopped (Bit2)
12
INTEGER
* No item can be set through SNMP.
Power Unit 1
Detection
Obtains the Power Unit 1 status.
normal: Indicates Power Unit 1 output is normal.
abnormal: Indicates Power Unit 1 output is not detected.
notInstalled: Indicates Power Unit 1 is not installed when turned on.
Power Unit 1 DC
Output
Obtains the Power Unit 1 DC output status.
normal: Indicates Power Unit 1 DC output is normal.
abnormal: Indicates Power Unit 1 DC output is abnormal.
notInstalled: Indicates Power Unit 1 is not installed when turned on.
Power Unit 1 FAN
Status
Obtains the Power Unit 1 FAN status.
normal: Indicates the FAN DC output is normal.
stopped: Indicates the FAN DC output is abnormal.
notInstalled: Indicates Power Unit 1 is not installed when turned on.
Power Unit 2
Detection
Obtains the Power Unit 2 status.
normal: Indicates Power Unit 2 output is normal.
abnormal: Indicates Power Unit 2 output is not detected.
notInstalled: Indicates Power Unit 2 is not installed at the point of powered
on.