12. Specifications and Dimensions
12-1. Specifications
12-1-1. USF-212S
Number of Modules
Max. 12
Genlok Input
BB: 0.429Vp-p (NTSC)/0.45Vp-p (PAL) or
Tri-level Sync: 0.6Vp-p
2 inputs: 75
Ω BNC x 1 and Loop-through BNC x 1 for each
(Terminate with 75
Ω terminator, if unused.)
Interface
Ethernet
100BASE-TX / 1000BASE-T RJ-45 x 2 (LAN 1, LAN 2)
100BASE-TX RJ-45 x 1 (LAN A)
GPI
9-pin D-sub Female
Temperature
0°C to 40°C
Humidity
30% to 90% (no condensation)
Power
100 to 240 V AC ±10%, 50/60 Hz
Power Consumption
670VA (at 100 to 120V AC at maximum output current)
660VA (at 220 to 240V AC at maximum output current)
Dimensions
440 (W) x 88 (H) x 401 (D) mm
Weight
10 kg (Including 1 unit of power supply)
Consumables
(Recommended replacement timespans at room temperature for 24 hour operation)
Power unit: Within 5 years
Cooling fan: Within 6 years
12-1-2. USF-212PS
Power Supply
100 to 240 V AC 50/60Hz
Power Consumption
670VA (at 100 to 120V AC at maximum output current)
660VA (at 220 to 240V AC at maximum output current)
Maximum Output Current
+12 V DC 58.4 A
Dimensions
68.6 (W) x 41.3 (H) x 397 (D)mm
Weight
2.5 kg
Temperature
0°C to 40°C
Humidity
30% to 90% (no condensation)