2 TECHNICAL CHARACTERISTICS AND DIMENSIONS
2.1 Technical characteristics
This is an heating unit with a cast iron heat exchanger with three
combustion gas passes that operates an oil-fired blown-air burner
and a DHW water tank.
The following models are available:
CTF 23:
unit with open combustion chamber and heat output of
24 kW;
CTF 33:
unit with open combustion chamber and heat output of
33 kW;
CTFD 23:
unit with sealed combustion chamber and halved emis-
sions and heat output of 24 kW;
CTFD 33:
unit with sealed combustion chamber and halved emis-
sions and heat output of 33 kW;
The unit meets all of the standards in force in the country of desti-
nation that is indicated on the technical card.
The installation in a different country than the one specified could
be a source of danger to persons, animals and things.
The main technical features of these heating units are given
below:
Manufacture characteristics
- High-efficiency cast-iron heat exchanger with three combustion
gas passes
- Fiberglas insulation with extra thick aluminised kraft (50 mm)
- Oil-fired blown air burner in the balance flue version with built-in
fuel oil pre-heater
- Body in electro-galvanised sheet steel, painted with epoxypolye-
ster powders
- Unit electronic management card
- Heating expansion vessel with 8 litre capacity
- Heating safety valve at 3 bar
- Three speed heating circulator
- Single speed domestic hot water circulator
- Heating system de-aerator
- Copper coil for DHW instantaneous production
- Ready for connection to a programmable timer
- Oil filter
- Heating and hot water temperature sensor
- Domestic hot water priority flow sensor
- Loading valve of heating system
- Heating system drainage valve
- Safety device for water shortage
- Safety thermostat (110°C)
- Predisposition for the connection of a card for the management of
several heating zones (optional kit)
- Predisposition for connection to a Remote Control (optional kit)
- Possibility of connection of an external sensor to the Remote
Control (optional)
Operator interface
- General luminous switch
- SUMMER, WINTER, ANTI-FREEZE selector
- Regulator of the temperature of the heating water
- Regulator of the temperature of the domestic hot water
- LED thermometer
- Manometer
- Lights indicating:
· Power on
· Burner operation
· Heating function activated
· Burner shutdown
· Shutdown due to overheating
· Blockage due to insufficient system pressure
· Blockage due to malfunctioning of the temperature sensor
· Communication error with Remote Control
Operational characteristics
- Anti-freeze function
- Pump anti-blockage function
- Pump post-circulation function
- Heat absorption function