background image

Caution   

 

page  2 

General information for installers, service engineers  and user  

page  3 

1 Instructions for the user  

page  5

 

1.1 Control panel  

page  5 

1.2 How the heating unit operates 

page  6 

  1.2.1 Start-up 

page  6 

  1.2.2 Operation 

page  6 

  1.2.3 Unit shutdown 

page  6 

   

1.2.3.1 Burner shutdown 

page  7 

   

1.2.3.2 Shutdown due to overheating  

page  7

   

1.2.3.3 Shutdown due to low pressure in the system 

page  7

   

1.2.3.4 Shutdown due to malfunction of temperature probes  

page  7

1.3 Maintenance  

page  7 

1.4 Informations for the user 

page  7 

2 Technical features and dimensions 

page  8

 

2.1 Technical features  

page  8 

2.2 Dimensions  

page  9 

2.3 Unit scheme 

page  9 

2.4 Unit technical data 

page  10

2.5 Burner technical data 

page  10

3 Instructions for the installer  

page  11

 

3.1 Installation regulations 

page  11 

3.2 Installation  

page  11 

  3.2.1 Packaging  

page  11 

  3.2.2 Choose where to install the unit 

page  11 

  3.2.3 Installing the unit 

page  11 

  3.2.4 Connections to fuel oil mains supply 

page  11 

  3.2.5 Ventilation  

page 11 

  3.2.6 Air intake and flue gas discharge pipes  

page 11 

  3.2.7 Types and classification of air intake and flue gas discharge pipes 

page 12 

  3.2.8 Measuring combustion efficency  

page 13 

  3.2.9  Connections to power mains 

page 13 

  3.2.10 Plumbing connections  

page 13 

3.3 Filling the Central Heating Circuit 

page 13 

3.4 Starting up the unit 

page 14 

  3.4.1 Preliminary checks 

page 14 

  3.4.2 Switching on and off 

page 14 

  3.4.3 Burner regulation 

page 14

3.5 Plumbing diagram 

page 13 

3.6 Wiring diagram 

page  14

4 Oil burner  

page 15 

4.1 Description 

page 15 

4.2 Mounting the burner on the heating unit 

page 15 

4.3 Plumbing system 

page 15 

4.4 Regulating combustion 

page 16 

4.5 Removing the nozzles 

page 16 

4.6 Regulating the electrodes 

page 16 

4.7 Replacing the control unit 

page 17 

4.8 Burner ignition 

page 17 

4.9 Wiring diagram 

page 18 

4.10 Burner troubleshooting 

page 18 

5 Testing the heating unit 

page 19

 

5.1 Preliminary checks 

page 19 

5.2 Switching on and off 

page 19 

6 Maintenance 

page 19

 

6.1 Maintenance schedule 

page 19

7 Trouble-shooting 

page 20

INDICE

4

Содержание CAPRI C

Страница 1: ...CAPRI C IST 03 C 201 01 INSTALLATION USE AND MAINTENANCE GB...

Страница 2: ...Dear Customer Thank you for choosing and buying one of our boilers Please read these instructions carefully in order to install operate and maintain this equipment properly...

Страница 3: ...se of the packaging as all the materials can be recycled The packaging must therefore be sent to specific waste management sites Keep the packaging out of the reach of children as by its nature it may...

Страница 4: ...nnections to fuel oil mains supply page 11 3 2 5 Ventilation page 11 3 2 6 Air intake and flue gas discharge pipes page 11 3 2 7 Types and classification of air intake and flue gas discharge pipes pag...

Страница 5: ...mote control is interrupted or there are signal passage difficulties Once the connection is restored the light will turn off and the boiler will resume operation 7 Indication light red when the light...

Страница 6: ...a fixed value of 50 C in order to speed the response time should there be a demand for domestic hot water The MAINTENANCE function is not enabled when the selector is in the ANTI FREEZE position DOME...

Страница 7: ...osed as pressure increa ses boiler CH safety valve may open and water flow out Should boiler frequently shut down due to insufficient water pres sure have it serviced by an Authorized Service Centre o...

Страница 8: ...th epoxypolye ster powders Unit electronic management card Heating expansion vessel with 8 litre capacity Heating safety valve at 3 bar Three speed heating circulator Single speed domestic hot water c...

Страница 9: ...PRIORITY FLOW METER BR BURNER S2 DHW PROBE PS DHW PUMP TS LIMIT THERMOSTAT TA1 ROOM THERMOSTAT OPTIONAL 1 FLOW G 3 4 M 2 DHW G 1 2 M 3 RETURN G 3 4 M 4 COLD WATER G 1 2 M fig 3 D mm CTF 150 CTFD 120 A...

Страница 10: ...temperature setting range C 50 82 Maximum CH working pressure bar 3 3 CH expansion vessel capacity l 12 12 DHW temperature setting range C 35 57 Maximum DHW working pressure bar 6 6 DHW supply T 30K l...

Страница 11: ...elivery and return pipes Join the unit to the chimney and to the air intake pipe for D versions Connect the burner to the fuel oil supply pipes see sub section 3 2 4 Connect the unit to the power main...

Страница 12: ...ble thermal insu lation min 50 mm IMPORTANT When flue gas system is discharged through pipes diameter 125 mm it is compulsory to install on the air intake pipe an 80 mm diameter terminal similar to th...

Страница 13: ...e connected to the respective G 1 2 fittings on the heating unit The mains pressure must not be more that 6 bar otherwise a pres sure reducer needs to be provided The pressure in the DHW circuit shoul...

Страница 14: ...he safety valve is not blocked Check for water leaks 3 4 2 Switching on and off For instructions on how to switch the heating unit on and off refer to the User Manual 3 4 3 Burner regulation After sta...

Страница 15: ...stem If you need to work with a single pipe unscrew the cap 2 and re move the grub screw 3 Afterwards replace the cap 2 pic 17 Important With twin tube systems before starting up the burner make sure...

Страница 16: ...air can be regulated by turning the socket screw A shown in pic 11 The setting is shown on a graduated scale B The oil pressure can be regulated by turning screw 5 in pic 17 Refer to the technical da...

Страница 17: ...e high voltage wires pic 14 pic 13 4 8 Burner ignition In the event of shutdown the red be pressed to reset The burner ignition cycle is light 7 on the control panel pic 25 summarised in the graphs in...

Страница 18: ...s pre washing proce dure and then shuts down The photoresistance is dirty Clean it The photoresistance is faulty Replace it The flame goes out or does not light Check the oil pressure Check that oil f...

Страница 19: ...ating unit to be serviced and repaired by an authorised Service Centre which can provide properly trained quali fied personnel Before carrying out any maintenance involving the replacement of componen...

Страница 20: ...solved Flow probe is faulty Flow probe is disconnected Replace it Flow probe is faulty Replace it The boiler has shut down and red light no 6 is flashing Boiler will automatically resume operation as...

Страница 21: ...21...

Страница 22: ...22...

Страница 23: ...23...

Страница 24: ...Via Cerreto 40 Tel 0365 878 31 e mail fondital fondital it www fondital it The manufacturer reserves the right to modify the data contained herein at any time without notice Uff Pubblicit Fondital IST...

Отзывы: