Manual # 26-0002901-00 / Revision H ScreenPro - High Resolution Seamless Switcher
43
Input Contrast Adjust
ICNT op nnn sclr
Description:
Adjusts the Input Contrast values.
Parameters:
op
-
Select Contrast Control;
[C|R|G|B] Common, Red Offset, Green Offset, Blue Offset
nnn
- Contrast value, C Range 75 - 125%, RGB Range -25 - 25%
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
Example:
ICNT C 100.8 A: Adjusts the Common Input Contrast value as 100.8%.
ICNT G 15: Adjusts the Green Contrast Offset to 15% on Scaler A.
Input Clock Phase Adjust
ICPH op sclr nn
Description:
Adjust the Input Clock Phase.
Parameters:
op
- [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nn
– Phase Number [0 – 31] when
op
=
M
Number to Increment by when
op
=
I
nn
–
File Number [0 – 64]
Example:
ICPH A P: Automatically adjust the Input Clock Phase on Preview.
ICPH M M 12 0: Set Input Clock Phase on Main to 12 for the currently displayed input.
ICPH M M 12 2: Set Input Clock Phase for File Number 2 to 12.
ICPH I A 3: Increment the Input Clock Phase on Scaler A by 3.
Input Clock Phase Offset Adjust
ICPHO op sclr nn
Description:
Adjust the Input Clock Phase Offset.
Parameters:
op
- [A|D|M|I] Automatic | Debug | Manual | Increment
Note: Debug Mode is for Factory Use Only
sclr
- Scaler [A|B|M|P]; Scaler A | Scaler B | Main | Preview
nn
– Phase Offset Number [-16 – 15] when
op
=
M
Number to Increment by when
op
=
I
nn
–
File Number [0 – 64]
Example:
ICPHO A P:
Automatically adjust the Input Clock Phase Offset on
Preview.
ICPHO M M 12 0:
Set Input Clock Phase Offset on Main to 12 for the currently displayed input.
ICPHO M A 12 2:
Set Input Clock Phase Offset for File Number 2 to 12. If the scaler A source
displayed is derived from File Number 2, it will be updated as well.
ICPHO I A 3:
Increment the Input Clock Phase Offset on Scaler A by 3.