Operating instructions - mobiSERVE
6
SHORT/LONG PRESS ON THE RESET KEY
The value indicated is changed in the direction defined by
the arrow.
■
■
One unit for each short press on the TOTAL key.
■
■
Continuously, when the TOTAL key is kept depressed.
The speed with which the value is increased raises when
the key is held down.
If the required value is exceeded, repeat the procedure
from point 5.
7
LONG PRESS ON THE RESET KEY
The mobiSERVE is informed that the calibration procedure
is finished.
Before executing this operation, make sure that the
indicated value corresponds to the desired vale.
8
NO OPERATION
After the calculation, the new USER K FACTOR is indicated
for some seconds, then, the restart procedure is repeated in
order to finally get into the standby mode.
ATTENTION: From that moment, the value indicated is the
new calibration factor used by the counter, and it remains
so also after a battery replacement.
9
NO OPERATION
The mobiSERVE stores the new operating calibration factor
and is ready for discharge with the USER K FACTOR just
calculated.
10. Configuration of the mobiSERVE counter
The counter features a menu allowing the user to choose the main measuring unit: quarters (QTS), Pints
(PTS), Liters (L), Gallons (GAL).
The combination of the measuring units of the partial amount and total amount registers is defined in the
following table:
Combination No.
Measuring unit
Partial amount register
Measuring unit
Total amount register
1
Liters (L)
Liters (L)
2
Gallons (GAL)
Gallons (GAL)
3
Quarts (QTS)
Gallons (GAL)
4
Pints (PTS)
Gallons (GAL)