NOTE
6 digits are available to indicate the total amounts, plus two icons x10/x100.
The increase is done with the following sequence:
0,0 ---> 99999,9 ---> 999999 ---> 100000 x10 --->
999999 x10 ---> 100000 x100 ---> 999999 x100.
8.1 Discharge in normal mode
During standard discharge, the counter simultaneously displays the partial amount issued and the
resettable total amount RESET TOTAL.
An unintended pressing of the RESET or TOTAL key during counting has no effect.
Some seconds after fluid discharge, the display of the lower register changes from the resettable total
amount to the absolute total amount: The message RESET over the word TOTAL goes out and the value
of the resettable total amount is replaced by the absolute total amount.
This state is called pause (or standby) and remains unchanged as long as the user does not carry out any
operations at the counter.
8.1.1 Resetting the partial amount
The register of the partial amount can be reset to zero by pressing the
RESET key, when the counter is in the standby mode, i. e. when TOTAL
is shown in the display.
After pressing the RESET key, i. e. when zero reset is executed, the
display shows successively all digits switched on and off.
Following this operation, at first the partial amount reset to zero and
then RESET TOTAL is indicated.
And after a few seconds, RESET TOTAL is replaced by TOTAL, the total
amount NOT resettable.