7. Assembly
The mobiSERVE is supplied with assembly included.
Depending on the version, the attachments can or must be fitted.
NOTE
During assembly, pay attention to cleanliness and to an exact connection
and precise sealing.
WARNING
■
■
Before connecting the unit to the power supply system, the correct
insulation of the power cord must be checked.
8. Daily use
The mobiSERVE is supplied ready for use.
The trolley is immediately ready for use, even after long periods of storage.
The only operation required for daily use is to reset the registers of the partial and/or resettable total
amount to zero.
Then, the two screens for normal operation are called up. The first screen indicates the partial amount
and the resettable total amount RESET TOTAL. The other screen shows the partial amount and the ab-
solute total amount TOTAL. The transition from the resettable total amount to the absolute quantity is
done automatically and is performed within a period of time defined during manufacturing. It cannot
be changed by the user.
Register of
RESETTABLE
TOTAL VOLUME
Register of
ABSOLUTE
TOTAL VOLUME
Register of partial volume
The register of the absolute total amount TOTAL cannot be reset to zero by the user. It will continuously
increase over its whole lifetime. The registers of the two total amounts RESET TOTAL and TOTAL take the
same space and the same digits on the display. This is the reason why the two total amounts will never
appear together, but are always shown alternately.
The mobiSERVE is programmed in a way that the one or the other total amount is displayed at certain
moments:
■
■
The absolute total amount TOTAL is shown in the standby mode of the counter.
■
■
The resettable total amount RESET TOTAL is displayed at the following moments:
- For a short time (some seconds) after the partial amount has been reset to zero.
- During discharge of fluid.
Some seconds after fluid discharge, this short time time span has elapsed and the counter changes to the
standby mode. The display of the lower register shows the absolute total amount.