11
Operating instructions - mobiSERVE
GB
5.1 Filling operation
■
■
Approach the mobiSERVE to the vehicle to be refilled.
■
■
During filling, the parking brake should be always applied at the rear castors in order to prevent an
uncontrolled movement of the trolley.
■
■
Insert the nozzle valve into the tank opening and turn the main switch on.
■
■
The pump starts to work.
■
■
The following information is indicated on the control panel: battery charge level, counted daily amount
and total amount.
■
■
Open the nozzle valve. As soon as the filling operation is completed, turn the main switch off again.
NOTE
The mobiSERVE is optionally delivered with a nozzle valve which allows to
carry out a filling operation according to ISO 22241-5. Please refer to the
operating instructions supplied with unit for information on the operation of
the nozzle valve according to ISO 22241-5.
5.2 Adjusting the flow rate
The mobiSERVE is equipped with a flow rate control unit.
The infinitely variable flow rate can be adapted to the vehicle to be filled.
■
■
To do this, turn the rotary knob "Flow Rate" in the range from min to max. The current flow rate can be
indicated in the display.
Refer to
a
Paragraph 8.1.3. Discharge and display of the current flow rate (flow rate mode).
6. Technical data
Designation
mobiSERVE 200 l
25 352; 25 352 836
mobiSERVE 60 l
25 353; 25 353 836
Pump design
Diaphragm pump, self-priming
Delivery rate under free discharge
l/min
10-20, infinitely variable
6-12, infinitely variable
Discharge pressure up to
bar
1,7
Pumping media
Urea (AdBlue®) or water
Motor data
Power consumption
A
18
Voltage
V
12 V DC
Fuse
A
25
Protection class
IP
54
Charger
Operating voltage
V
230 V AC
Frequency
Hz
50-60
Power consumption
A
0,6
Charging current
A
5
Accu
Voltage
V
12 V DC
Capacity
Ah
24
Charging time when battery
completely empty
h
5
Connecting cable, length
m
1,2
Weight
kg
85
62
Dimensions LxWxH
mm
1000 x 800 x 1080
780 x 550 x 1080
Hose length
m
4
2
Nominal width hose
mm
19
13,5
Tab. 6-1: Technical data