Operating Manual EMGZ 321.EIP
19.10.2017
13
3.10
Relays Outputs
The EMGZ321._.EIP amplifier provides 2 programmable relay outputs. The outputs
are software controlled. Electrically they are potential-free. Each relay output can
individually be configured to check violations of force limits. The outputs are
configured in chapter 8.6 “Relay Parameter Group”.
Following functions can be assigned to each output:
•
Indicate if force limit of sensor A has be violated
•
Indicate if force limit of sensor B has be violated
•
Indicate if the sum of the forces of sensor A+B has be violated
•
Indicate if the absolute value of difference
׀
A-B
׀
has be violated
For more details about the functions refer to paragraph 8.7 “Description Relay
Parameter Group”.
Hardware access via screw terminals (see Fig. 4 and 5)
Signal Name
Terminal #
Relay 1/1
7
Relay 1/2
8
Relay 2/1
9
Relay 2/2
10