Operating Manual EMGZ 321.EIP
19.10.2017
30
8.3
Description of Amplifier Parameters
Offset A
Offset B
LCD:
Offset A
LCD:
Offset B
Use:
With the Offset Compensation procedure you can automatically
compensate the roller weight. It is always performed before the
calibration procedure. The value for offsetting the roller weight is stored
in the parameter
Offset
in
the parameter group Amplifier.
Unit
Parameter Range
Selection
Default
Min
Max
Digit -8000 +8000
-
0
Nominal Force Sensor A
Nominal Force Sensor B
LCD:
NomForcA
LCD:
NomForcB
Use:
This parameter stores the nominal force of your force measuring roller.
The nominal force is printed on the label of each force sensor. Enter the
forces that have been installed in the measuring roller individually for
sensor A and sensor B.
Unit
Parameter Range
Selection
Default
Min
Max
N, kN, g,
kg, lb
1)
1.0 100’0000.0
-
1000.0
1)
The display shows the unit of measure that was previously selected