Operating Manual EMGZ 321.EIP
19.10.2017
45
Relay Parameter Group
Parameter
LCD
Unit
Min
Max
Selection
5)
Default
Relay 1
Assignment of
Relay 1 function
Relay 1
-
-
-
Chk A
Chk B
Chk A+B
Chk
׀
A-B
׀
Disable
Chk A+B
Limit condition
check Relay 1
LimCond1
4)
- - -
< Limit
> Limit
< Limit
Limit value R1
Limit 1
N
1)
0.1 200’000.
0
- 100.0
Relay 2
Assignment of
Relay 2 function
Relay 2
-
-
-
Chk A
Chk B
Chk A+B
Chk
׀
A-B
׀
Disable
Chk IA+BI
Limit condition
check Relay 2
LimCond2
4)
- - -
< Limit
> Limit
> Limit
Limit value R2
Limit 2
N
1)
0.1 200’000.
0
- 100.0
1)
The display shows the unit of measure that was previously selected
4)
This parameter is only displayed, if the function check “Limit 1” or “Limit 2” have
been assigned to Relay 1 respectively Relay 2.
5)
A relay function can only be assigned once to a relay output. If a function is being
used the function will not appear on the parameter selection.