Operating Manual EMGZ 321.EIP
19.10.2017
41
Unit of Measure
LCD:
Unit
Use:
This parameter determines the unit system used
.
Note:
By changing the units to
lb
the whole unit system will change
from metric to imperial units.
Unit
Parameter Range
Selection
Default
Min
Max
- - -
N
kN
g
kg
lb
N
Display Filter
LCD:
Dis.Filt
Use:
The amplifier provides a lowpass filter to prevent noise disturbing the
LSD or to steady high fluctuation of the force values on the display.
The parameter
Dis.Filt
stores the cut off frequency of the filter. The
lower the cut off frequency, the more sluggish the display will be. A
correctly tuned filter will steady the value shown in the display.
Unit
Parameter Range
Selection
Default
Min
Max
Hz 0.1 10.0
-
1.0
Ethernet IP Address
LCD:
IP Addr.
Use:
The parameter assigns an IP address to the amplifier. This enables the
user to communicate via a web browser with the amplifier that is
imbedded in a network. The IP address must be entered in 4 separate
blocks (IP Bl. 1; IP Bl. 2; IP Bl. 3; and IP Bl. 4)
Unit
Parameter Range
Selection
Default
Min
Max
-
000.000
000.000
255.255.
255.255
-
192.168.
000.090