Operating Manual CMGZ411/421
24
LOCK<CR>
PACC<CR> / FAIL<CR>
disable controller, lock
REMR<CR>
PACC<CR> / FAIL<CR>
turn off remote mode
REMS<CR>
PACC<CR> / FAIL<CR>
turn on remote mode
SOLLXXXXX<CR> PACC<CR> / FAIL<CR>
write new tension reference into RAM
SRMP<CR>
XXXXX<CR>
read actual tension reference
STEL<CR>
XXX.X<CR>
read actual output signal
SWRTXXXXX<CR> PACC<CR> / FAIL<CR>
write new tension reference into EEPROM
STAR<CR>
XXXXXXXXXXXXXXXXXX<CR>
general status information
1-6 : feedback
7-11
:
output
12-16: reference after ramp
17 :
error evaluation
18 :
controller error
VALA<CR>
XXXXXX<CR>
feedback channel A (CMGZ 421)
VALB<CR>
XXXXXX<CR>
feedback channel B (CMGZ 421)
VALS<CR> XXXXXX<CR>
feedback
A+B
11.3
Write parameters
Command Answer
Purpose
WP01XXXXX<CR> PACC<CR> / FAIL<CR>
offset feedback channel A
WP02X.XXX<CR> PACC<CR> / FAIL<CR>
gain feedback channel A
WP03XXXXX<CR> PACC<CR> / FAIL<CR>
offset feedback channel B (CMGZ 421)
WP04X.XXX<CR> PACC<CR> / FAIL<CR>
gain feedback channel B (CMGZ 421)
WP05X.XXX<CR> PACC<CR> / FAIL<CR>
value gain 1 -> channel A
WP06X.XXX<CR> PACC<CR> / FAIL<CR>
value gain 1 -> channel B (CMGZ 421)
WP07XXXX<CR> PACC<CR> / FAIL<CR>
nominal force
WP08X<CR>
PACC<CR> / FAIL<CR>
unit force
WP09X.X<CR>
PACC<CR> / FAIL<CR>
sensitivity
WP10X<CR>
PACC<CR> / FAIL<CR>
1 or 2 sensors
WP11XXX.X<CR> PACC<CR> / FAIL<CR>
filter feedback
WP12XX.X<CR>
PACC<CR> / FAIL<CR>
filter instrument A+B
WP13XX.X<CR>
PACC<CR> / FAIL<CR>
filter instrument A (CMGZ 421)
WP14XX.X<CR>
PACC<CR> / FAIL<CR>
filter instrument B (CMGZ 421)
WP15XX.X<CR>
PACC<CR> / FAIL<CR>
filter display
WP16XX.XX<CR> PACC<CR> / FAIL<CR>
scal. instrument A+B
WP17XX.XX<CR> PACC<CR> / FAIL<CR>
scal. instrument A (CMGZ 421)
WP18XX.XX<CR> PACC<CR> / FAIL<CR>
scal. instrument B (CMGZ 421)
WP19X<CR>
PACC<CR> / FAIL<CR>
limit 1 min / max
WP20XXXXX<CR> PACC<CR> / FAIL<CR>
limit value 1
WP21X<CR>
PACC<CR> / FAIL<CR>
limit 2 min / max
WP22XXXXX<CR> PACC<CR> / FAIL<CR>
limit value 2
WP23X<CR>
PACC<CR> / FAIL<CR>
language
WP24XX.X<CR>
PACC<CR> / FAIL<CR>
ramp reference
WP25X<CR>
PACC<CR> / FAIL<CR>
PID-configuration
WP26XX.XX<CR> PACC<CR> / FAIL<CR>
Proportional component P
WP27XXX.XX<CR> PACC<CR> / FAIL<CR>
Integral component I
WP28XX.XXX<CR> PACC<CR> / FAIL<CR>
Derivative component D
WP29XXX.X<CR> PACC<CR> / FAIL<CR>
alarm controller error
Содержание CMGZ411
Страница 5: ...Operating Manual CMGZ411 421 5 3 3 Block Diagram CMGZ411 C411000e 3 4 Block Diagram CMGZ421 C421000e ...
Страница 9: ...Operating Manual CMGZ411 421 9 7 2 Determination of the machine configuration C400001e ...
Страница 10: ...Operating Manual CMGZ411 421 10 C400002e ...
Страница 11: ...Operating Manual CMGZ411 421 11 C400003e ...
Страница 12: ...Operating Manual CMGZ411 421 12 C400004e ...
Страница 13: ...Operating Manual CMGZ411 421 13 C400005e ...