www.fmiproducts.com
125077-01D
27
TROUBLESHOOTING
WARNING: Turn off fireplace and let cool before servicing. Only
a qualified service person should service and repair fireplace.
CAUTION: Never use a wire, needle or similar object to clean
pilot. This can damage pilot unit.
Note: All troubleshooting items are listed in order of operation.
POSSIBLE CAUSE
1. No gas supply or shutoff
valve is OFF
2. Air in gas line
3. Construction debris clog
-
ging pilot orifice
4. Low gas pressure
5. Kinked pilot line
6. Control valve is not opening
7. No power to unit or ignition
module
REMEDY
1. Check to see if you have gas
supply and that equipment
shutoff valve is opened
2. Repeat lighting procedure
several times to purge all
air out of lines. If after re
-
peated attempts appliance
does not light, call for quali
-
fied service and repair
3. Remove debris and dirt,
inspect and clean any other
possible obstructions
4. Contact your gas supplier
to check pressure
5. Have a qualified technician
replace pilot line
6. Replace control valve (Re
-
fer to
Replacement Parts
,
page 26)
7. Check that main power is
on and that all wire connec
-
tions are made correctly to
ignition model (see
Wiring
Diagram
, page 23).
OBSERVED PROBLEM
Pilot will not light