Continued

Figure 1 - Direct Vent Fireplace 

(DVF-36NSR-C Shown)

Outer 

Glass 

Door

Log Set

Flue 

Collar

Nailing 

Flange

Center Brick/

Control Cover

Standard 

Brick 

Refractories

Andiron

Carefully supervise young chil

-

dren when they are in the room 

with fireplace.

Keep  the  area  around  your 

fireplace  clear  of  combustible 

materials,  gasoline  and  other 

flammable vapor or liquids. Do 

not  run  fireplace  where  these 

are used or stored.

1.  For  propane/LP  fireplace,  do  not  place 

propane/LP  supply  tank(s)  inside  any 

structure.  Locate  propane/LP  supply 

tank(s) outdoors. To prevent performance 

problems, do not use propane/LP fuel tank 

of less than 100 lb. capacity.

2.  If you smell gas

• shut off gas supply

• do not try to light any appliance

• do not touch any electrical switch; do not 

use any phone in your building

• immediately call your gas supplier from 

a neighbor’s phone. Follow the gas sup

-

plier's instructions

• if you cannot reach you gas supplier, call 

the fire department.

3.  Never install the fireplace

• in a recreational vehicle

• in windy or drafty areas where curtains or 

other combustible (flammable) objects can 

make contact with the fireplace front

• in high traffic areas

4.  Turn  fireplace  off  and  let  cool  before 

servicing,  installing  or  repairing.  Only  a 

qualified  service  person  should  install, 

service or repair this fireplace. Have fire

-

place  inspected  annually  by  a  qualified 

service person.

5.  You  must  keep  control  compartments, 

burners  and  circulating  air  passages 

clean.  More  frequent  cleaning  may  be 

needed  due  to  excessive  lint  and  dust 

from  carpeting,  bedding  material,  etc. 

Turn off the gas valve and pilot light before 

cleaning fireplace.

6.  Have venting system inspected annually 

by a qualified service person. If needed, 

have venting system cleaned or repaired. 

See 

Cleaning and Maintenance

, page 25.

7.  Do not use any solid fuels (wood, coal, 

paper, cardboard, etc.) in this fireplace. 

Use only the gas type indicated on fire

-

place nameplate.

8.  This appliance, when installed, must be 

electrically grounded in accordance with 

local  codes  or,  in  the  absence  of  local 

codes, with the 

National Electrical Code, 

ANSI/NFPA 70 or Canadian Electrical 

Code, CSA C22.1.

9.  Do not use fireplace if any part has been 

exposed to or under water. Immediately 

call a qualified service person to arrange 

for replacement of the unit.

10. Do  not  operate  fireplace  if  any  log  is 

broken.

11. Do not operate fireplace with glass door 

removed, cracked or broken.

12. Provide adequate clearances around air 

openings.

LOCAL CODES

Install and use fireplace with care. Follow all 

local codes. In the absence to local codes, 

use the current 

National Fuel Gas Code ANSI 

Z223.1/NFPA 54*

 (USA) or the current 

CSA-

B149.1 Installation Code

 (Canada).

*Available from:

American National Standards Institute, Inc.

1430 Broadway

New York, NY 10018

National Fire Protection Association, Inc.

Batterymarch Park

Quincy, MA 02269

PRODUCT 

IDENTIFICATION

Содержание DVF36NHI-C

Страница 1: ...yourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied in...

Страница 2: ...eplace designed for residential ap plications This fireplace must be installed with FMI PRODUCTS LLC vent pipe components and terminations Outside airflex installation is required for both horizontal...

Страница 3: ...fythisfireplaceunderanycircumstances Anyparts removed for servicing must be replaced prior to operating fireplace WARNING Do not use a blower insert heat exchanger insert or other accessory not approv...

Страница 4: ...e fire place inspected annually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint...

Страница 5: ...h traffic areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your fireplace is to be installed directly on carpeting vinyl tile or any combustible mate...

Страница 6: ...ce to combustible materials are for framing purpose only NOTICE Thisfireplaceisintend edforuseassupplementalheat Use this fireplace along with your primary heating system Do not install this fireplace...

Страница 7: ...n US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally...

Страница 8: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP...

Страница 9: ...e components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning applia...

Страница 10: ...cial twist lock con nections Twist Lock Procedure Female ends of pipes have locking lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe secti...

Страница 11: ...with provided wood screws see Figure 11 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before conne...

Страница 12: ...hart with critical minimum and maximum dimensions which MUST be met NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downwa...

Страница 13: ...above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space install...

Страница 14: ...the configurations for vertical termination VENTING INSTALLATION Continued Figure 18 Vertical Venting Configuration Vertical Venting V 40 max HIGH ALTITUDE INSTALLATION Your FMI PRODUCTS LLC direct v...

Страница 15: ...AK6 75 75 Outside Air Flex Vent Kit CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fireplace See retailer where you purch...

Страница 16: ...gulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down FIREPLACE INSTALLATION Continued Apply pipe joint sealant lightly to male NPT threads...

Страница 17: ...LP supply tank valve for propane LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys t...

Страница 18: ...oints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 23 REMOVING REPLACING GLASS DOORS CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass doorpa...

Страница 19: ...hinges see Figure 26 Set aside to avoid scratches or damage FIREPLACE INSTALLATION Continued 3 Follow these instructions in reverse to reinstall Removing and Installing Inner Door All Models 1 Remove...

Страница 20: ...ner Door Screen and Rod Non Cool Touch Models Only LAVA ROCK EMBER FLAKES AND SCRAP LOG INSTALLATION Lava rock ember flakes and scrap log pieces are included with your fireplace Install these items wh...

Страница 21: ...er and on burner ports see Figure 30 This will create the glowing ember ap pearance as the flame touches the ember flakes Do not block burner ports or pilot ports by overlapping ember flakes in one ar...

Страница 22: ...rn on all electric power to appliance 10 Turn safety shutoff switch to the ON posi tion 11 Visually locate pilot Ignitor should begin to spark and main burner should ignite once flame appears at pilot...

Страница 23: ...e appliance rocker switch is turned OFF the pilot will shut OFF when the main burner shuts OFF 3 When the continuous pilot switch is in the ON position and the appliance rocker switch is turned ON the...

Страница 24: ...and grounding stem If your pilot assembly does not meet these requirements Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size see Fi...

Страница 25: ...curing The glass should be cleaned several times with a non ammonia nonabrasive household clean er and warm water after the first two weeks of operation Thereafter clean the glass two or three times...

Страница 26: ...Minimum Inlet Supply Pressure 7 w c DVF 36PSR C DVF 36PHR C DVF 36PSI C DVF 36PHI C DVF 36PSR CC DVF 36PHR CC DVF 36PSI CC DVF 36PHI CC Rating 62 000 Btu hr Gas Type Propane LP Gas Only Ignition Elec...

Страница 27: ...valve is not opening 7 No power to unit or ignition module REMEDY 1 Checktoseeifyouhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air...

Страница 28: ...c connectors that plug in the face of the gas control valve Confirm the gas control valve is properly grounded to the module 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum...

Страница 29: ...s blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots...

Страница 30: ...F 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR CC DVF 36NHR CC DVF 36PHR CC DVF 36NSI CC DVF 36PSI CC DVF 36NHI CC AND DVF 36PHI CC 10 14 9 7 21 11 32 23 24 26 25 41...

Страница 31: ...ctor 1 20 106702 01 5 Gasket 1 21 120431 01 Burner Base Gasket 1 22 117997 01 Glass Door Retainer 1 23 120142 01 Firebox Leg 4 24 117891 01 Fireplace Handle 4 25 21171 Gas Conduit Cover 1 26 24460 Gas...

Страница 32: ...14 28 8 5 3 4 15 27 21 24 26 32 29 30 31 35 26 38 26 33 36 34 34 39 PARTS MODELS DVF 36NSR C DVF 36PSR C DVF 36NHR C DVF 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR...

Страница 33: ...3 8 x 18 1 25 125068 01 Battery Backup 1 26 125061 01 Valve Module Bracket 1 27 114365 24 Brass Orifice 32 NG 1 114365 16 Brass Orifice 51 LP 1 28 126117 01 Log Assembly 1 29 125063 01 Valve Motorize...

Страница 34: ...a 14 16 16 18 17 10 11a 11b 11c 11d 12b 12c 12d PARTS MODELS DVF 36NSR C DVF 36PSR C DVF 36NHR C DVF 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR CC DVF 36NHR CC DVF...

Страница 35: ...efractory Right Red 1 8 125142 01 Hearth Refractory Front Ivory 1 125142 02 Hearth Refractory Front Red 1 9 121128 01 Top Refractory Bracket 2 10 121182 01 Rear Refractory Bracket 1 11a 125152 01 Left...

Страница 36: ...C who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsas...

Отзывы: