FIREPLACE INSTALLATION
Continued
Figure 24 - Checking Gas Joints for
Propane/LP Gas Fireplace
Propane/LP
Supply Tank
Gas Valve
Equipment
Shutoff Valve
Figure 25 - Checking Gas Joints for
Natural Gas Fireplace
Gas Meter
Gas Valve
Equipment
Shutoff Valve
PRESSURE TESTING FIREPLACE GAS
CONNECTIONS
1. Open equipment shutoff valve (see Figure
23, page 17).
2. Open propane/LP supply tank valve for
propane/LP fireplace or main gas valve
located on or near gas meter for natural
gas fireplace.
3. Make sure control knob of fireplace is in
the OFF position.
4. Check all joints from equipment shutoff
valve to gas valve (see Figure 24 or Figure
25). Apply noncorrosive leak detection
fluid to all joints. Bubbles forming show a
leak. Correct all leaks at once.
5. Light fireplace (see
Operation
, page 21).
Check all other internal joints for leaks.
6. Turn off fireplace (see
To Turn Off Gas to
Appliance
, page 23).
REMOVING/REPLACING GLASS
DOORS
CAUTION: Do not operate
this fireplace with a broken glass
door panel or without the glass
door panel securely in place. For
replacement part information
see
Replacement Parts
, page 26.
CAUTION: Wear gloves and
safety glasses while handling or
removing broken glass. Do not
remove if glass is hot. Keep chil
-
dren and pets away from glass.
WARNING: If fireplace has
been running, turn off fireplace.
Let cool before removing glass
doors.
WARNING: More than one
person is required when replac
-
ing glass.
Standard Glass Models ending in -C have only
an inner door to be removed/replaced. Cool
Touch Glass Models ending in -CC have an
inner, middle and outer door.
Installing Middle Door (Cool Touch Glass
Models ending in -CC Only)
Middle door hangs on 2 hinges from top of
inner glass door (see Figure 26, page 19).
1. Remove middle door from packaging.
2. Angle middle door so top goes into fireplace
first. Hang middle door on brackets at top
of inner door (see Figure 26, page 19).