background image

www.fmiproducts.com

125077-01D

11

VENTING INSTALLATION

Continued

 WARNING: Do not recess 

vent termination into any wall. 

This will cause a fire hazard.

5. 

Noncombustible Exterior Wall:

 Position 

horizontal vent cap in center of the 8 

1

/

2

round  hole  and  attach  to  exterior  wall 

with four wood screws provided. Before 

attaching vent cap to exterior wall, run a 

bead  of  non-hardening  mastic  (pliable 

sealant) around outside edges to make a 

seal between it and outside wall.

 

Note: Four wood screws provided should 

be replaced with appropriate fasteners for 

stucco, brick, concrete or other types of 

sidings (see Figure 10).

 

Combustible  Exterior  Wall:

  For  vinyl 

siding, stucco or wood exteriors, a siding 

standoff may be installed between vent 

cap  and  exterior  wall.  Siding  standoff 

prevents excessive heat from damaging 

siding materials. Siding material must be 

cut to accommodate standoff. Bolt vent 

cap  to  standoff. Apply  non-hardening 

mastic around outside edge of standoff. 

Position  standoff/cap  assembly  in  the 

center of 11 

1

/

2

" square hole and attach to 

exterior wall with provided wood screws 

(see Figure 11). Siding standoff must sit 

flush against exterior fascia material.

6. 

Connecting Vent Cap with Horizontal 

Vent Pipe:

 Slide wall firestop over vent 

pipe before connecting horizontal run to 

vent cap (see Figure 12).

Figure 10 - Installing Horizontal Vent Cap 

(Noncombustible Exterior)

Wood 

Screw

Vent Cap

Figure 11 - Installing Siding Standoff 

(Combustible Exterior Wall)

Cut Siding Away to 

Fit Standoff

Wood 

Screw

Screws

Standoff

Vent 

Cap

Apply Mastic

to All Four Sides

Vent Cap 

(Horizontal 

Termination)

Interior Wall 

Surface

Wall 

Firestop

Horizontal 

Vent Pipe

Figure 12 - Connecting Vent Cap with 

Horizontal Vent Pipe

Screw

Apply 

Mastic to All 

Four Sides

 

Carefully  move  fireplace,  with  vent  as

-

sembly attached, toward wall and insert 

vent pipe into horizontal termination. Pipe 

overlap should be a minimum of 1 

1

/

4

" (see 

Figure 13, page 12).

 

Slide  wall  firestop  against  interior  wall 

surface and attach with screws provided. 

See  Figure  13,  page  12,  for  horizontal 

termination details.

 

Place fireplace into position and shim with 

noncombustible material if needed. Nail or 

screw side flanges to framing to secure 

unit in place.

 IMPORTANT:

 Make sure fire

-

place is level before securing. If fireplace 

is not level it will not work properly.

Содержание DVF36NHI-C

Страница 1: ...yourgassupplierfromaneighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Installation and service must be performed by a quali fied in...

Страница 2: ...eplace designed for residential ap plications This fireplace must be installed with FMI PRODUCTS LLC vent pipe components and terminations Outside airflex installation is required for both horizontal...

Страница 3: ...fythisfireplaceunderanycircumstances Anyparts removed for servicing must be replaced prior to operating fireplace WARNING Do not use a blower insert heat exchanger insert or other accessory not approv...

Страница 4: ...e fire place inspected annually by a qualified service person 5 You must keep control compartments burners and circulating air passages clean More frequent cleaning may be needed due to excessive lint...

Страница 5: ...h traffic areas windy or drafty areas or near furniture or draperies Proper clearances must be maintained If your fireplace is to be installed directly on carpeting vinyl tile or any combustible mate...

Страница 6: ...ce to combustible materials are for framing purpose only NOTICE Thisfireplaceisintend edforuseassupplementalheat Use this fireplace along with your primary heating system Do not install this fireplace...

Страница 7: ...n US if greater than 50 000 36 91 cm in Canada if greater than 100 000 K clearance to a mechanical air supply inlet In Canada 6 ft 1 83m minimum In US 3 ft 91 cm above if within 10 ft 3 m horizontally...

Страница 8: ...tly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment The sign shall read in print size no less than 1 2 in size GAS VENT DIRECTLY BELOW KEEP...

Страница 9: ...e components and terminations The venting system must terminate on the outside of the structure and can not be at tached to a chimney or flue system serving a separate solid fuel or gas burning applia...

Страница 10: ...cial twist lock con nections Twist Lock Procedure Female ends of pipes have locking lugs indentations These lugs will slide straight into match ing slots on male ends of adjacent pipes Push pipe secti...

Страница 11: ...with provided wood screws see Figure 11 Siding standoff must sit flush against exterior fascia material 6 Connecting Vent Cap with Horizontal Vent Pipe Slide wall firestop over vent pipe before conne...

Страница 12: ...hart with critical minimum and maximum dimensions which MUST be met NOTICE Donotsealtermination cap to vent pipe Cap must be removable for vent inspection and maintenance WARNING Never run vent downwa...

Страница 13: ...above ceiling is an insulated ceiling or an attic nail firestop from top side This prevents loose insula tion from falling into required clearance space If area above ceiling is a living space install...

Страница 14: ...the configurations for vertical termination VENTING INSTALLATION Continued Figure 18 Vertical Venting Configuration Vertical Venting V 40 max HIGH ALTITUDE INSTALLATION Your FMI PRODUCTS LLC direct v...

Страница 15: ...AK6 75 75 Outside Air Flex Vent Kit CHECK GAS TYPE Use proper gas type for the fireplace unit you are installing If you have conflicting gas types do not install fireplace See retailer where you purch...

Страница 16: ...gulator with Vent Pointing Down Propane LP Only Propane LP Supply Tank External Regulator with Vent Pointing Down FIREPLACE INSTALLATION Continued Apply pipe joint sealant lightly to male NPT threads...

Страница 17: ...LP supply tank valve for propane LP gas fireplace or opening main gas valve located on or near gas meter for natural gas fireplace or using compressed air 4 Check all joints of gas supply piping sys t...

Страница 18: ...oints for leaks 6 Turn off fireplace see To Turn Off Gas to Appliance page 23 REMOVING REPLACING GLASS DOORS CAUTION Do not operate thisfireplacewithabrokenglass door panel or without the glass doorpa...

Страница 19: ...hinges see Figure 26 Set aside to avoid scratches or damage FIREPLACE INSTALLATION Continued 3 Follow these instructions in reverse to reinstall Removing and Installing Inner Door All Models 1 Remove...

Страница 20: ...ner Door Screen and Rod Non Cool Touch Models Only LAVA ROCK EMBER FLAKES AND SCRAP LOG INSTALLATION Lava rock ember flakes and scrap log pieces are included with your fireplace Install these items wh...

Страница 21: ...er and on burner ports see Figure 30 This will create the glowing ember ap pearance as the flame touches the ember flakes Do not block burner ports or pilot ports by overlapping ember flakes in one ar...

Страница 22: ...rn on all electric power to appliance 10 Turn safety shutoff switch to the ON posi tion 11 Visually locate pilot Ignitor should begin to spark and main burner should ignite once flame appears at pilot...

Страница 23: ...e appliance rocker switch is turned OFF the pilot will shut OFF when the main burner shuts OFF 3 When the continuous pilot switch is in the ON position and the appliance rocker switch is turned ON the...

Страница 24: ...and grounding stem If your pilot assembly does not meet these requirements Turn the adjustment screw marked PILOT clockwise to decrease or counterclockwise to increase the flame to proper size see Fi...

Страница 25: ...curing The glass should be cleaned several times with a non ammonia nonabrasive household clean er and warm water after the first two weeks of operation Thereafter clean the glass two or three times...

Страница 26: ...Minimum Inlet Supply Pressure 7 w c DVF 36PSR C DVF 36PHR C DVF 36PSI C DVF 36PHI C DVF 36PSR CC DVF 36PHR CC DVF 36PSI CC DVF 36PHI CC Rating 62 000 Btu hr Gas Type Propane LP Gas Only Ignition Elec...

Страница 27: ...valve is not opening 7 No power to unit or ignition module REMEDY 1 Checktoseeifyouhavegas supply and that equipment shutoff valve is opened 2 Repeat lighting procedure several times to purge all air...

Страница 28: ...c connectors that plug in the face of the gas control valve Confirm the gas control valve is properly grounded to the module 1 Check electrical connec tions 1 Clean and adjust pilot flame for maximum...

Страница 29: ...s blocked 3 Improper venting or exces sive blockage 4 Excessive amounts of em bers and pan material OBSERVED PROBLEM Gas odor even when gas control valve is off Gas odor during combustion Glass soots...

Страница 30: ...F 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR CC DVF 36NHR CC DVF 36PHR CC DVF 36NSI CC DVF 36PSI CC DVF 36NHI CC AND DVF 36PHI CC 10 14 9 7 21 11 32 23 24 26 25 41...

Страница 31: ...ctor 1 20 106702 01 5 Gasket 1 21 120431 01 Burner Base Gasket 1 22 117997 01 Glass Door Retainer 1 23 120142 01 Firebox Leg 4 24 117891 01 Fireplace Handle 4 25 21171 Gas Conduit Cover 1 26 24460 Gas...

Страница 32: ...14 28 8 5 3 4 15 27 21 24 26 32 29 30 31 35 26 38 26 33 36 34 34 39 PARTS MODELS DVF 36NSR C DVF 36PSR C DVF 36NHR C DVF 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR...

Страница 33: ...3 8 x 18 1 25 125068 01 Battery Backup 1 26 125061 01 Valve Module Bracket 1 27 114365 24 Brass Orifice 32 NG 1 114365 16 Brass Orifice 51 LP 1 28 126117 01 Log Assembly 1 29 125063 01 Valve Motorize...

Страница 34: ...a 14 16 16 18 17 10 11a 11b 11c 11d 12b 12c 12d PARTS MODELS DVF 36NSR C DVF 36PSR C DVF 36NHR C DVF 36PHR C DVF 36NSI C DVF 36PSI C DVF 36NHI C DVF 36PHI C DVF 36NSR CC DVF 36PSR CC DVF 36NHR CC DVF...

Страница 35: ...efractory Right Red 1 8 125142 01 Hearth Refractory Front Ivory 1 125142 02 Hearth Refractory Front Red 1 9 121128 01 Top Refractory Bracket 2 10 121182 01 Rear Refractory Bracket 1 11a 125152 01 Left...

Страница 36: ...C who will provide original factory replacement parts Failure to use original factory replacement parts voids this warranty Travel handling transportation diagnostic material laborandincidentalcostsas...

Отзывы: