TECHNICAL SERVICE
You may have further questions about
installation, operation, or troubleshooting.
If so, contact FMI PRODUCTS, LLC at
1-866-328-4537. When calling please have
your model and serial numbers of your
fireplace ready.
You can also visit FMI PRODUCTS, LLC’s
web site at
www.fmiproducts.com
.
REPLACEMENT PARTS
Note: Use only original replacement parts.
This will protect your warranty coverage for
parts replaced under warranty.
Contact authorized dealers of this product.
If they can’t supply original replacement
part(s), call FMI PRODUCTS, LLC at
1-866-328-4537.
When calling, have ready:
• your name
• your address
• model and serial numbers of your fireplace
• how fireplace was malfunctioning
• purchase date
Usually, we will ask you to return the part to
the factory.
SERVICE HINTS
When Gas Pressure Is Too Low
• pilot will not stay lit
• burners will have delayed ignition
• fireplace will not produce specified heat
• propane/LP gas supply might be low (pro
-
pane/LP units only)
You may feel your gas pressure is too low. If
so, contact your local gas supplier.
SPECIFICATIONS
DVF-36NSR-C, DVF-36NHR-C,
DVF-36NSI-C, DVF-36NHI-C,
DVF-36NSR-CC, DVF-36NHR-CC,
DVF-36NSI-CC, DVF-36NHI-CC
• Rating: 66,000 Btu/hr
• Gas Type: Natural Gas Only
• Ignition: Electronic
• Manifold Pressure: 3.5" w.c.
• Minimum Inlet Supply Pressure: 7" w.c.
DVF-36PSR-C, DVF-36PHR-C,
DVF-36PSI-C, DVF-36PHI-C,
DVF-36PSR-CC, DVF-36PHR-CC,
DVF-36PSI-CC, DVF-36PHI-CC
• Rating: 62,000 Btu/hr
• Gas Type: Propane/LP Gas Only
• Ignition: Electronic
• Manifold Pressure: 10" w.c.
• Minimum Inlet Supply Pressure: 11" w.c.
CLEANING AND MAINTENANCE
Continued
PILOT AND BURNERS
• Remove material before cleaning burners
and replace when cleaning is complete.
• Burner and controls should be cleaned with
compressed air to remove dust, dirt or lint.
• Use a vacuum cleaner or small, soft bristled
brush to remove excess dust, dirt or lint.
LOGS
• Use a vacuum cleaner to remove any carbon
buildup on logs.
• Replace material periodically as needed.
See
Replacement Parts
, page 26.
VENTING SYSTEM
Conduct annual inspection of the venting
system following these guidelines:
1. Check areas of venting system that are
exposed to the weather for corrosion (rust
spots or streaks and, in extreme cases,
holes). Have these items replaced imme
-
diately by a qualified service person.
2. Remove the vent cap and shine a flashlight
into the vent. Remove any foreign mate
-
rial.
3. Check for evidence of excessive con
-
densation. Continuous condensation can
cause corrosion of caps, pipes and fittings
and can be caused by having excessive
lateral runs, too many elbows or exterior
portions of the system being exposed to
cold weather.
4. Inspect joints to verify that no pipe section
or fitting has been disturbed and loosened.
Check mechanical supports such as wall
straps for rigidity.