Wireless DC Clamp
Calibration
17
Figure 8. Calibration Connections for the 4-20 mA Clamp
Table 7. Calibration Steps for the 4-20 mA Clamp
Function
Step
Display
Calibrator Output
mA DC
1
POS
20 mA,0 Hz
2
0A
0 mA
3
C-01
-20 mA,0 Hz
4
0A
0 mA
5
C-02
20 mA,0 Hz
6
0A
0 mA
7
C-03
-100 mA,0 Hz
8
0A
0 mA
9
C-04
100 mA,0 Hz
5522A