LIMITED WARRANTY AND LIMITATION OF LIABILITY

Each Fluke product is warranted to be free from defects in material and workmanship under normal use and 
service. The warranty period is one year and begins on the date of shipment. Parts, product repairs, and 
services are warranted for 90 days. This warranty extends only to the original buyer or end-user customer of 
a Fluke authorized reseller, and does not apply to fuses, disposable batteries, or to any product which, in 
Fluke's opinion, has been misused, altered, neglected, contaminated, or damaged by accident or abnormal 
conditions of operation or handling. Fluke warrants that software will operate substantially in accordance with 
its functional specifications for 90 days and that it has been properly recorded on non-defective media. Fluke 
does not warrant that software will be error free or operate without interruption.

Fluke authorized resellers shall extend this warranty on new and unused products to end-user customers only 
but have no authority to extend a greater or different warranty on behalf of Fluke. Warranty support is 
available only if product is purchased through a Fluke authorized sales outlet or Buyer has paid the applicable 
international price. Fluke reserves the right to invoice Buyer for importation costs of repair/replacement parts 
when product purchased in one country is submitted for repair in another country.

Fluke's warranty obligation is limited, at Fluke's option, to refund of the purchase price, free of charge repair, 
or replacement of a defective product which is returned to a Fluke authorized service center within the 
warranty period.

To obtain warranty service, contact your nearest Fluke authorized service center to obtain return 
authorization information, then send the product to that service center, with a description of the difficulty, 
postage and insurance prepaid (FOB Destination). Fluke assumes no risk for damage in transit. Following 
warranty repair, the product will be returned to Buyer, transportation prepaid (FOB Destination). If Fluke 
determines that failure was caused by neglect, misuse, contamination, alteration, accident, or abnormal 
condition of operation or handling, including overvoltage failures caused by use outside the product’s 
specified rating, or normal wear and tear of mechanical components, Fluke will provide an estimate of repair 
costs and obtain authorization before commencing the work. Following repair, the product will be returned to 
the Buyer transportation prepaid and the Buyer will be billed for the repair and return transportation charges 
(FOB Shipping Point).

THIS WARRANTY IS BUYER'S SOLE AND EXCLUSIVE REMEDY AND IS IN LIEU OF ALL OTHER 
WARRANTIES, EXPRESS OR IMPLIED, INCLUDING BUT NOT LIMITED TO ANY IMPLIED WARRANTY 
OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE. FLUKE SHALL NOT BE LIABLE 
FOR ANY SPECIAL, INDIRECT, INCIDENTAL, OR CONSEQUENTIAL DAMAGES OR LOSSES, 
INCLUDING LOSS OF DATA, ARISING FROM ANY CAUSE OR THEORY.

Since some countries or states do not allow limitation of the term of an implied warranty, or exclusion or 
limitation of incidental or consequential damages, the limitations and exclusions of this warranty may not 
apply to every buyer. If any provision of this Warranty is held invalid or unenforceable by a court or other 
decision-maker of competent jurisdiction, such holding will not affect the validity or enforceability of any other 
provision.

11/99

Fluke Corporation
P.O. Box 9090
Everett, WA 98206-9090
U.S.A.

Fluke Europe B.V.
P.O. Box 1186
5602 BD Eindhoven
The Netherlands

Содержание A3003 FC

Страница 1: ...December 2017 2017 Fluke Corporation All rights reserved All product names are trademarks of their respective companies a3003 FC a3004 FC Wireless DC Clamp Calibration Manual...

Страница 2: ...nearest Fluke authorized service center to obtain return authorization information then send the product to that service center with a description of the difficulty postage and insurance prepaid FOB D...

Страница 3: ...ord 9 Performance Tests 10 Test the Display 10 Test the Backlight 10 Clamp Input and Keypad Test 10 DC Voltage Verification 11 4 20 mA Clamp Performance Test 12 2000 A Clamp Performance Test 13 2000 m...

Страница 4: ...ii a3003 a3004 FC Calibration Manual...

Страница 5: ...ating instructions see www fluke com Contact Fluke To contact Fluke use one of these telephone numbers Technical Support USA 1 800 44 FLUKE 1 800 443 5853 Calibration Repair USA 1 888 99 FLUKE 1 888 9...

Страница 6: ...ts Have an approved technician repair the Product Use only specified replacement parts Comply with local and national safety codes Use personal protective equipment approved rubber gloves face protect...

Страница 7: ...tation W WARNING RISK OF DANGER X WARNING HAZARDOUS VOLTAGE Risk of electric shock Do not apply around or remove from uninsulated hazardous live conductors without taking additional protective measure...

Страница 8: ...a3003 FC a3004 FC Calibration Manual 4 Figure 1 a3003 FC Wireless DC Clamp Figure 2 a3004 FC Wireless DC Clamp 20 00A DC CU RR EN T CL AM P i20 00 Tactile Barrier Tactile Barrier...

Страница 9: ...erature Operating Temperature 10 C 50 C Storage Temperature 40 C 60 C Temperature coefficient Add 0 1 X specified accuracy C 18 C or 28 C Operating Relative Humidity 90 at 35 C 75 at 40 C 45 at 50 C A...

Страница 10: ...quipment is connected to a test object Korea KCC Class A Equipment Industrial Broadcasting Communication Equipment Class A Equipment meets requirements for industrial electromagnetic wave equipment an...

Страница 11: ...to show The first digit flashes 3 Push and enter the first digit of the password Default is 1234 4 Push and enter the next digit of the password until all digits are entered 5 Push to confirm the inpu...

Страница 12: ...t enclosure touching or handling any PCBs or components Minimize handling Handle static sensitive parts by non conductive edges Do not slide static sensitive components over any surface When removing...

Страница 13: ...acement 2 Use a Phillips screwdriver to remove the bottom case screws Two of the screws are inside the battery door 3 Keep the PCA in the top case 4 Apply 3 0 V across the battery contacts on the PCA...

Страница 14: ...2 Push while you keep pushed until all of the display segments are shown See Figure 4 If segments of the display are missing contact Fluke for repair See Contact Fluke Figure 4 Display Segments Test...

Страница 15: ...y b Push The Meter is in verification mode 2 Connect the Calibrator to test leads and three of the six leads in the cable as shown in Figure 5 The white lead connects to the NORMAL Hi terminal of the...

Страница 16: ...r the signal to stabilize d Record the reading Table 3 a3003 and a3004 DC Meter Performance Verification Test Connection Calibrator Output Resolution Specification UUT Reading Limits a3003 a3004 1 Yea...

Страница 17: ...ode 4 Push on the Meter 5 For each value in Table 5 a Zero the Meter b Apply the Calibrator Output value to the Meter c Wait 4 seconds for the signal to stabilize d Record the reading All readings mus...

Страница 18: ...ure 6 Calibration Connections for 2000 A Clamp 1 4 7 STBY 5522A CALIBRATOR HIGH CURRENT OUTPUT LO W CURRENT OUTPUT 850V PK MAX 850V PK MAX 30A PK 7V PK MAX 180A PK 7V PK MAX HI LO HI LO 3V PK 300mA PK...

Страница 19: ...the performance tests do the calibration adjustment procedure Note The first calibration of the Product is available from the Fluke factory only Meter Calibration Adjustment Before you can adjust the...

Страница 20: ...r 3 Use 1 loop insulated copper wire to short circuit the calibrator current output AUX and LO terminals see Figure 8 4 Clamp the 4 20 mA current clamp around the insulated copper wire Current flow sh...

Страница 21: ...nction Step Display Calibrator Output mA DC 1 POS 20 mA 0 Hz 2 0A 0 mA 3 C 01 20 mA 0 Hz 4 0A 0 mA 5 C 02 20 mA 0 Hz 6 0A 0 mA 7 C 03 100 mA 0 Hz 8 0A 0 mA 9 C 04 100 mA 0 Hz 5522A 0 HI LO TC 1000V RM...

Страница 22: ...til 0 A shows When 0 A shows on the display the balance adjustment passes Continue with the calibration To do the calibration adjustment 1 Move the jaw to the 3 kA coil 2 Power on all the equipment an...

Страница 23: ...ssible damage to the Product or to equipment under test Remove batteries to prevent battery leakage and damage to the Product if it is not used for an extended period Be sure that the battery polarity...

Страница 24: ...a3004 FC Calibration Manual 20 Replaceable Parts User replaceable parts and accessories are shown in Table 9 Table 9 User Replaceable Parts Description Fluke Part Number Battery Door 4583058 Batterie...

Отзывы: