6 Installation
FLUXUS WD
6.2 Transducers
39
UMFLUXUS_WDV1-3EN, 2018-07-16
• Place the tension strap around the pipe and insert it into the clasp, see Fig. 6.19.
• Tighten the tension strap.
• Tighten the clasp screw.
Ratchet clasp
• Insert the tension strap into the tension strap clamp and the metal spring, see Fig. 6.21. The metal spring does not have to be
mounted on:
– steel pipes
– pipes with an outer pipe diameter < 80 mm
– pipes that are not subjected to significant temperature fluctuations
• Position the ratchet clasp, tension strap clamp and metal spring (if necessary) on the pipe, see Fig. 6.17:
– on a horizontal pipe, mount the tension strap clamp on the side of the pipe, if possible
– mount the metal spring (if necessary) opposite to the tension strap clamp
• Place the tension strap around the pipe and pass it through the slot of the clasp screw, see Fig. 6.22.
• Tighten the tension strap.
• Cut off the protruding tension strap, see Fig. 6.22.
• Tighten the clasp screw.
Fig. 6.18:
Tension strap with clamp
Fig. 6.19:
Tension strap with quick release
clasp and metal spring
1 – tension strap clamp
1 – clasp screw
2 – metal spring
Fig. 6.20:
Tension strap with band clamp clasp
1 – clasp screw
Caution!
The edge of the tension strap is very sharp.
Risk of injury!
→
Debur sharp edges.
→
Wear the required personal protective equipment. Observe the applicable rules.
Notice!
In order to release the screw and the tension strap, press the lever down, see Fig. 6.22.
1
2
1
1
Содержание FLUXUS WD
Страница 1: ...FLUXUS WD UMFLUXUS_WDV1 3EN Operating instruction...
Страница 6: ...Table of contents FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 6...
Страница 150: ...18 Settings 18 9 Key lock FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 150...
Страница 171: ...Annex FLUXUS WD D Conformity declarations 171 UMFLUXUS_WDV1 3EN 2018 07 16 D Conformity declarations...
Страница 172: ...Annex D Conformity declarations FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 172...
Страница 173: ......
Страница 174: ......