14 Outputs
14.1 Configuration of a binary output
FLUXUS WD
2018-07-16, UMFLUXUS_WDV1-3EN
114
Output function test
The function of the output can now be tested.
• Connect a multimeter to the output.
• Select
Yes
to test the output. Select
No
to display the next menu item.
• Press ENTER.
• Select
On
to test the energized state of the output.
• Press ENTER.
The value has to be low ohmic.
• Select
Off
to test the de-energized state of the output.
• Press ENTER.
The value has to be high ohmic.
• Select
Repeat
to repeat the test,
Finish
to display the next menu item.
• Press ENTER.
.
• Select
Yes
to test the status of the output signal. Select
No
to display the next menu item.
• Press ENTER.
• Select in the scroll list
Status OK
or
Status error
.
• Press ENTER.
Depending on the selected switching condition, the value has to be either high or low ohmic.
• Select
Repeat
to repeat the test,
Finish
to display the next menu item.
• Press ENTER.
14.1.2
Output of the event value
Switching function (idle state)
• Select the switching function, see Tab. 14.3.
• Press ENTER.
Options\Channel A\Outputs\...\Test signal B1
Options\Channel A\Outputs\...\Enter test value B1
Options\Channel A\Outputs\...\Test mea. range B1
Options\Outputs\...\Enter test value B1
Source item
Switching function
(Idle state)
Output info
Test signal
Test mea. range
Options\Channel A\Outputs\...\Idle state
Содержание FLUXUS WD
Страница 1: ...FLUXUS WD UMFLUXUS_WDV1 3EN Operating instruction...
Страница 6: ...Table of contents FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 6...
Страница 150: ...18 Settings 18 9 Key lock FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 150...
Страница 171: ...Annex FLUXUS WD D Conformity declarations 171 UMFLUXUS_WDV1 3EN 2018 07 16 D Conformity declarations...
Страница 172: ...Annex D Conformity declarations FLUXUS WD 2018 07 16 UMFLUXUS_WDV1 3EN 172...
Страница 173: ......
Страница 174: ......