3 General principles
3.4 Undisturbed flow profile
FLUXUS WD
2018-07-16, UMFLUXUS_WDV1-3EN
18
Tab. 3.1:
Recommended distance from disturbance sources
D – nominal pipe diameter at the measuring point
l – recommended distance between disturbance source and transducer position
disturbance source: 90° elbow
inlet: l
≥
10 D
outlet: l
≥
5 D
disturbance source: 2 × 90° elbows on different planes
inlet: l
≥
40 D
outlet: l
≥
5 D
disturbance source: valve
inlet: l
≥
40 D
outlet: l
≥
5 D
disturbance source: reducer
inlet: l
≥
10 D
outlet: l
≥
5 D
disturbance source: pump
inlet: l
≥
20 D
l
l
l
l
l
l
l
l
l
Содержание FLUXUS WD