9 Measurement
FLUXUS F60*
9.2 Measurement settings
89
UMFLUXUS_F60xV5-0EN, 2017-10-16
9.2
Measurement settings
9.2.1
Selection of the physical quantity and the unit of measurement
The following physical quantities can be measured:
• sound speed
• flow velocity: is calculated on the basis of the measured transit time difference
• volumetric flow rate: is calculated by multiplying the flow velocity by the cross-sectional
pipe area
• mass flow rate: is calculated by multiplying the volumetric flow rate by the operating
density of the fluid
• heat flow: is calculated from the volumetric flow rate, the measured temperatures of the
supply and return lines, and the heat flow coefficients of the fluid
The physical quantity is selected as follows:
• Select the program branch
Output Options
.
• Press ENTER.
• Select the channel for which the physical quantity is to be entered (here:
channel A
).
• Press ENTER.
• Select the physical quantity in the scroll list.
• Press ENTER.
Output Options
for Channel A:
Physic. Quant.
Unit Of Measure
Damping
see annex A, p. 221
Output Options
Output Options\for Channel A:
Output Options\for Channel A:\Physic. Quant.