15 Data logger
15.1 Activating/deactivating the data logger
FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
136
15
Data logger
The transmitter has a data logger which stores the data during the measurement.
The following data will be stored:
• date
• time
• measuring point number
• pipe parameters
• fluid parameters
• transducer data
• sound path (reflection or diagonal arrangement)
• transducer distance
• damping factor
• storage rate
• physical quantity
• unit of measurement
• measured values (physical quantity and input quantities)
• values of the totalizers (in case the totalizers are activated)
• diagnostic values (in case the storing of diagnostic values is activated)
In order to store the data, the data logger has to be activated.
The available data logger can be displayed.
The storing of each measured value will be signalized acoustically. The acoustic signal
can be deactivated.
15.1
Activating/deactivating the data logger
• Select the channel for which the output is to be activated in the program branch
Output Options
.
• Press ENTER.
• Press ENTER until
Store Meas.Data
is displayed. Select
yes
to activate the data
logger,
no
to deactivate it.
• Press ENTER.
Output Options\for Channel A:
Output Options\...\Store Meas.Data
Содержание FLUXUS F60 Series
Страница 1: ...FLUXUS F60 UMFLUXUS_F60xV5 0EN Operating instruction...
Страница 218: ...21 Heat flow measurement 21 6 Steam in inlet FLUXUS F60 2017 10 16 UMFLUXUSF60xV5 0EN 218...
Страница 241: ...Annex FLUXUS F60 D Conformity declarations 241 UMFLUXUS_F60xV5 0EN 2017 10 16 D Conformity declarations...
Страница 242: ...Annex D Conformity declarations FLUXUS F60 2017 10 16 UMFLUXUSF60xV5 0EN 242...
Страница 243: ......
Страница 244: ......