3 General principles
FLUXUS F60*
3.4 Undisturbed flow profile
25
UMFLUXUS_F60xV5-0EN, 2017-10-16
disturbance source: valve
inlet: l
≥
40 D
outlet: l
≥
5 D
disturbance source: reducer
inlet: l
≥
10 D
outlet: l
≥
5 D
disturbance source: pump
inlet: l
≥
20 D
Tab. 3.1:
Recommended distance from disturbance sources
D – nominal pipe diameter at the measuring point
l – recommended distance between disturbance source and transducer position
l
l
l
l
l