7 Connection
7.2 FLUXUS *608
FLUXUS F60*
2017-10-16, UMFLUXUSF60xV5-0EN
60
7.2
FLUXUS *608
7.2.1
Transducers
FLUXUS *608**-A2
The connections are on the upper side of the transmitter, see Fig. 7.11.
• Remove the blind plug, see Fig. 7.12.
• Insert the connector of the transducer cable into the socket of the transmitter. The red
point (a) on the connector has to be aligned with the red marking (b) on the socket, see
Fig. 7.13.
Danger!
Risk of explosion when using the transmitter FLUXUS *608**-A2 in
explosive atmospheres
This may result in personal or material damage or other dangerous situa-
tions.
→
Observe the "Safety instructions for the use in explosive atmospheres",
(see document SIFLUXUS_608).
Danger!
Risk of explosion when using the transmitter FLUXUS *608**-F2 in
explosive atmospheres
This may result in personal or material damage or other dangerous situa-
tions.
→
Observe the "Safety instructions for the use in explosive atmospheres",
see document SIFLUXUS_608F2).
Fig. 7.11:
Connection of the transducers to the transmitter
1 – transducers (measuring channel A)
2 – transducers (measuring channel B)
CH A
COMM
Input
Output
CH B
DC-IN
1
2
Содержание FLUXUS F60 Series
Страница 1: ...FLUXUS F60 UMFLUXUS_F60xV5 0EN Operating instruction...
Страница 218: ...21 Heat flow measurement 21 6 Steam in inlet FLUXUS F60 2017 10 16 UMFLUXUSF60xV5 0EN 218...
Страница 241: ...Annex FLUXUS F60 D Conformity declarations 241 UMFLUXUS_F60xV5 0EN 2017 10 16 D Conformity declarations...
Страница 242: ...Annex D Conformity declarations FLUXUS F60 2017 10 16 UMFLUXUSF60xV5 0EN 242...
Страница 243: ......
Страница 244: ......