© 1999-2007 QualityWaterForLess.com
- 13 -
•
The display should now show “CT / Fl” as shown in figure 37. (This indicates
Control Type METER IMMEDIATE Format)
Do not change this value, and
press the “Extra Cycle Button” once to continue
.
FIGURE 36
FIGURE 37
•
The display should now show “NT / - - - 2” as shown in figure 38 below. (This
indicates Number of Tanks is Dual)
Do not change this value, and press the
“Extra Cycle Button” once to continue
.
•
The display should now show “TS / - U 1 -” or “TS / - U 2 -” as shown in figure
39 below. (This indicates which tank is currently in service)
Do not change this
value, and press the “Extra Cycle Button” once to continue
.
FIGURE 38
FIGURE 39
•
The display should now show “C / 24.0” as shown in figure 40 on the following
page. (This indicates the Capacity is 32,000 grains)
Use the “UP” or “DOWN”
button to change this value to the size of your system, and press the “Extra
Cycle Button” once to continue when finished.
•
The display should now show “H / 20” as shown in figure 41 on the following
page. (This indicates the Hardness is 20 grains)
Use the “UP” or “DOWN”
button to change this value to the total hardness of you water (as calculated
on page 10), and press the “Extra Cycle Button” once to continue when
finished.