Remove the filling funnel and duct tape and repeat for the second tank. After
the second tank is filled, go on to the next section
Installing the Fleck 9100SXT Meter Control Valve:
•
Using the included silicone lubricant packet, lubricate the inner and outer o-
rings on the bottom of the Fleck 9100SXT Meter Valve as shown in Figures 5
& 6 below. Please repeat this for the main valve, and the secondary portion, as
shown below.
FIGURE 5
FIGURE 6
•
Next, place the Fleck 9100SXT Meter Valve and secondary portion onto the
top of each tank, being sure that the riser tube fits into the central o-ring on
each, as shown in figures 7 & 8 below. Hand tighten each to the tank snugly
by hand only.
NOTE: Do not use Teflon tape or pipe dope on the valve or
tank threads.
FIGURE 7
FIGURE 8
•
Locate the yoke and/or bypass valve assembly that was shipped with your
system. Also, disassemble the plumbing adaptor clips as shown in Figures 8 &
9 on the following page.