18
DAILY OPENING PROCEDURES
NOTE:
YOUR HANDS SHOULD BE CLEANED
AND SANITIZED BEFORE YOU PERFORM
THE FOLLOWING PROCEDURES.
NOTE:
THE FOLLOWING PROCEDURES
REQUIRE APPROVED, SERVICEABLE AND
SANITIZED TOOLS AND BRUSHES.
CONTACT YOUR LOCAL DISTRIBUTOR FOR
RECOMMENDED SUPPLIES.
NOTE:
USE AN APPROVED CLEANER AND
SANITIZER FOR THE FOLLOWING
PROCEDURES. REFER TO
MANUFACTURER’S INSTRUCTIONS FOR
PROPER PREPARATIONS OF THESE
CLEANING AGENTS.
NOTE:
INSPECT ALL WEAR ITEMS AND
REPLACE IF NECESSARY.
Ensure that the Blending Assembly has been
disassembled and cleaned according to the
DAILY CLOSING PROCEDURES. This is
typically performed at the close of the previous
business day.
Sanitizing the Blending System
1. Prepare an approved sanitizer solution
according to manufacturer’s instructions.
2. Remove the Manifold cap and set it on a
sanitary tray. Spray the 9-Tube Assembly
Manifold opening with approved sanitizer
solution and allow it to sanitize for at least 1
minute. (See Figure 8.)
Figure 8
3. Place the 9-Tube Assembly in a container to
catch the sanitizer solution. (See Figure 9.)
Figure 9
4. Place only the Blending Head portion in an
approved sanitizer solution, keeping the
Drive Motor above the water line. Press
WATER / SYRUP FLUSH to sanitize the
enclosed auger. Allow the Blending Head
to soak for at least 1 minute. (See
Figure 10.)
WATER
LINE
DRIVE
MOTOR
Sanitizer
26066
Figure 10
5. Hang the Blending Assembly and the 9-
Tube Assembly on the Accessory Hanging
Bracket to dry. (See Figure 11.)
26198
Figure 11
Содержание FB 80Sa-08
Страница 5: ...4 General System Overview 26000 2 1 3 5 7 9 10 11 8 6 4 12 Figure 1...
Страница 11: ...10 Syrup Pump and Related Parts 6 7 5 8 9 10 4 3 26004 1 1D 1C 1A 1E 1B 2 2B 2A 2D 2C Figure 4...
Страница 15: ...14 Electronic Parts and Connections 26006 4A 4 4B 4C 1 2 5 7 7 9 13 9 7 10 16 15 11 7 6 12 14 8 3 9 Figure 6...
Страница 18: ...17...
Страница 22: ...21...
Страница 30: ...29...
Страница 58: ...57...
Страница 72: ...71...