60
Revision 10 – 1/09/2015
FTS 370d/w/r
Local Tower Config
The Local Tower Configuration menu
simplifies system installation by allowing
each SC 370 to discover and bind with its
connected external components.
The
binding process allows the controller to
assign an address to each of the connected
external components without the need to
manually address dipswitches or configure
jumpers. Additional programming options
in this menu include:
AOL beacon
selection, Catenary level selection and L-
810 marker programming.
Discover Tower
The discovery and binding procedure is
required
for systems consisting of two or
more SC 370 units or any GPS enabled
system.
The discovery and binding
procedure is not required, but is
highly
recommended
for single SC 370 systems.
The procedure must be performed during
initial system installation and when control
components
are
replaced.
Please
familiarize yourself with the following steps
before performing this procedure.
1. Remove
power
from
the
lighting
system at the source.
2. Allow 5 minutes for the output voltage
to completely drain from all SC 370
units. Measure the output voltage on
each SC 370 unit at TB2 DC+ and
DC-. Verify that the voltage is less
than 5V DC before proceeding.
3. Select the SC 370 unit for the binding
procedure. Open fuse holders F1 and
F2 located on TB1 of all other SC 370
units in the system.
4. Restore the source power to the
lighting system. Only the SC 370 unit
selected in the previous step should be
operational.
5. Select Discover Tower in the Local
Tower Configuration menu and follow
the on-screen instructions.
6. All discovered connected components
will be displayed at the bottom of the
screen. Press Enter to accept. Move
the * to Yes and press Enter two times
to confirm the binding procedure.
7. Repeat the procedure for all remaining
SC 370 units in the system.
Unbind Tower
If an error occurs during the binding
procedure or a control component is
replaced, you must use the Unbind Tower
option to remove the previously assigned
address. Follow the steps in the Unbind
menu option.
The Discover Tower
procedure must be repeated after the
Unbind Tower request is completed.
AOL Beacon
Dual lighting systems require that the
malfunction of any uppermost red beacon
place the entire system in white night
backup. The AOL Beacon option allows
the uppermost beacons to be programmed
to meet this requirement. All SC 370 units
connected to an uppermost beacon must be
programmed as AOL beacon.
Marker Settings
The Marker Settings menu provides access
to program the total number of L-810
markers connected to each SC 370 unit.
Additionally,
each
marker’s
power
consumption
can
be
manually
or
automatically
sensed
and
a
normal
operating threshold established.
This
feature helps to ensure the system’s
compatibility with future marker designs.
It also simplifies the replacement of
marker fixtures by allowing different
models of Flash Technology approved
markers to be installed in the same system.
Содержание VANGUARD FTS 370d
Страница 2: ......
Страница 36: ...24 Revision 10 1 09 2015 FTS 370d w r Figure 2 5 Marker Interface Wiring ...
Страница 50: ...38 Revision 10 1 09 2015 FTS 370d w r Figure 2 19 Typical D1 D2 System Wiring Diagram PHD 512 PHOTODIODE ...
Страница 54: ...42 Revision 10 1 09 2015 FTS 370d w r Figure 2 21 Typical Catenary System Wiring Diagram ...
Страница 94: ...This page intentionally left blank ...
Страница 96: ...84 Revision 10 1 09 2015 FTS 370d w r Figure 6 1 SC 370 AC Component Locations ...