90
Revision 10 – 1/09/2015
FTS 370d/w/r
Appendix A: Vanguard (v3.1) SNMP V2c INFORM TRAPs
Vanguard supports SNMP V2c INFORM TRAPs to notify SNMP managers of field
events. Any INFORM that is not acknowledged within 20 minutes will be resent every 20
minutes until it is acknowledged; up to 24 hours.
SNMP TRAPs do not require
acknowledgement.
This document describes the default severities for INFORMs.
The
severity setting and name for all INFORMs is configurable via the Vanguard web interface or
SNMP sets.
Vanguard SNMP INFORM TRAPs Default Severities
Critical
INFORMs, whose default severity setting is set to Critical, are those which indicate a
NOTAM worthy event. The set of Critical INFORMs would be the minimum set required to
handle to ensure proper monitoring.
See Table A-1 for a list of Critical INFORMs and their descriptions.
Warning
INFORMs, whose default severity setting is set to Warning, are those which indicate
maintenance is needed on a component of the lighting system, but would not necessarily
require a NOTAM.
In some situations these INFORMs may be as important as the Critical
events and in others they may not.
See Table A-2 for a list of Warning INFORMs and their descriptions.
Info
INFORMs, whose default severity setting is set to ‘Info’, do not indicate NOTAM worthy
events; although some of them may accompany the Critical INFORMs as additional
diagnostic information.
See Table A-3 for a list of Informational INFORMs and their descriptions.
Содержание VANGUARD FTS 370d
Страница 2: ......
Страница 36: ...24 Revision 10 1 09 2015 FTS 370d w r Figure 2 5 Marker Interface Wiring ...
Страница 50: ...38 Revision 10 1 09 2015 FTS 370d w r Figure 2 19 Typical D1 D2 System Wiring Diagram PHD 512 PHOTODIODE ...
Страница 54: ...42 Revision 10 1 09 2015 FTS 370d w r Figure 2 21 Typical Catenary System Wiring Diagram ...
Страница 94: ...This page intentionally left blank ...
Страница 96: ...84 Revision 10 1 09 2015 FTS 370d w r Figure 6 1 SC 370 AC Component Locations ...