FTS 370d/w/r
Revision 10 – 1/09/2015
91
Table A-1 – Critical INFORMs
Name
Default
Severity
Description
OID
whiteDayAlarmNotify
Critical
White Day Alarm (DAY ALARM):
The connected flash head is exhibiting a white
day alarm.
.1.3.6.1.4.1.9882.1.2.1.1.1
whiteNightAlarmNotify
Critical
White Night Alarm (WNIGHT ALARM):
The connected flash head is exhibiting a white
night alarm.
.1.3.6.1.4.1.9882.1.2.1.1.2
redNightAlarmNotify
Critical
Red Night Alarm (RNIGHT ALARM):
The connected flash head is exhibiting a red
night alarm.
.1.3.6.1.4.1.9882.1.2.1.1.3
beaconCommunicationAlarmNotify
Critical
Beacon Communication Alarm (BCN COMM):
The SC 370X is experiencing a communications
failure with the connected flash head.
.1.3.6.1.4.1.9882.1.2.1.1.4
photodiodeAlarmNotify
Critical
Photodiode Alarm (PD ALARM):
System 1 Only. More than 19 hours have
passed since the system has changed modes via
the photodiode input.
.1.3.6.1.4.1.9882.1.2.1.1.5
systemPowerFailureAlarmNotify
Critical
System Power Failure Alarm (POWER FAIL):
System 1 only. Primary input power failure.
PCB 1 is operating on battery backup to provide
alarm INFORM.
.1.3.6.1.4.1.9882.1.2.1.1.11
towerLightingConfigurationAlarmNotify
Critical
Tower Lighting Configuration Alarm (CFG
ALARM):
Indicates that the system is detecting devices
that it is currently not configured to support.
For Example 3 Beacons are detected but the
site is configured for 2.
.1.3.6.1.4.1.9882.1.2.1.1.17
towerLightingSyncAlarmNotify
Critical
Tower Lighting Sync Alarm (TWR SYNC):
System 1 only. One or more subordinate units
have not synchronized with System 1 for a
period of one hour or more.
.1.3.6.1.4.1.9882.1.2.1.1.20
plcBindingsAlarmNotify
Critical
PLC Bindings Alarm (BIND ALARM):
System 1 only.
The BIND ALARM can be generated by either of
the following conditions:
• One or more controllers are not bound
correctly. A 'SYS COMM' alarm will accompany
the 'BIND ALARM'.
• Two or more controllers are bound to the
same connected equipment (beacon or marker
tier). A 'SYS COMM' alarm will not accompany
the 'BIND ALARM' in this instance. The most
noticeable symptom is a beacon that is not
flashing in 'Sync.' with the rest of the system.
This alarm can be corrected by unbinding then
binding the tower.
.1.3.6.1.4.1.9882.1.2.1.1.21
Содержание VANGUARD FTS 370d
Страница 2: ......
Страница 36: ...24 Revision 10 1 09 2015 FTS 370d w r Figure 2 5 Marker Interface Wiring ...
Страница 50: ...38 Revision 10 1 09 2015 FTS 370d w r Figure 2 19 Typical D1 D2 System Wiring Diagram PHD 512 PHOTODIODE ...
Страница 54: ...42 Revision 10 1 09 2015 FTS 370d w r Figure 2 21 Typical Catenary System Wiring Diagram ...
Страница 94: ...This page intentionally left blank ...
Страница 96: ...84 Revision 10 1 09 2015 FTS 370d w r Figure 6 1 SC 370 AC Component Locations ...