![Flaem RF7 Dual Speed Plus Скачать руководство пользователя страница 8](http://html1.mh-extra.com/html/flaem/rf7-dual-speed-plus/rf7-dual-speed-plus_instruction-manual_2302023008.webp)
8
SOFTTOUCH FACE MASKS
During inspiration the vent
bends inwards.
During expiration the vent bends
outwards.
The new SoftTouch Masks feature an adaptive edge made
of a soft biocompatible material ensuring an excellent
adherence to the face and a Dispersion Limiting Vent.
These innovations, which make them stand out from the
rest, allow increased sedimentation of medication in the
lungs and reduced dispersion into the air.
Soft
biocompatible
material
Dispersion
Limiting Vent
HOW TO USE THE “RF7 DUAL SPEED PLUS” NEBULIZER WITH SPEED SELECTOR AND
VALVE
The nebulizer is professional fast and suitable for the administration of
all types of drugs, including the most expensive ones, also in patients
with chronic diseases. The geometry of the internal ducts of the RF7 Dual
Speed Plus nebulizer ensures the ideal particle size providing effective
treatment right down to the lower airways.
To make inhalation therapy faster, press with your finger on the MAX
marking on the speed selector with valve system (11.4). This configuration
is also suited for the use of nasal prongs 1, 2.
To make inhalation therapy more effective press with your finger on the
speed selector with valve system (11.4) opposite the MAX marking. In this
way the valve systems in the nebulizer, in the mouthpiece and in the mask
will ensure optimal medication delivery to the lower respiratory tract,
limiting dispersion of medication into the environment.
USE OF NEBULIZATION MANUAL CONTROL
To achieve continuous nebulisation action you should not use the manual nebulisation
control (8), especially in the case of children or persons with reduced physical, sensory, or
mental capabilities. The manual nebulisation control is useful for limiting dispersion of the
medication in the surrounding environment.
To start nebulizing close with a finger the
hole of the nebulizer manual
control (8) and breathe in gen-
tly; we recommend to hold your
breath for a moment so that the
inhaled aerosol droplets can be
deposited,
meanwhile, to disable nebulizing, remove
your finger from the hole of
the nebulizer manual control
to avoid the waste of drug, op-
timizing its acquisition. Then
exhale slowly.
MAX
Содержание RF7 Dual Speed Plus
Страница 28: ...28 8 8 8 SOFTTOUCH SoftTouch RF7 DUAL SPEED PLUS RF7 Dual Speed Plus 11 4 1 2 11 4 5 10 MAX...
Страница 38: ...38 SOFTTOUCH SoftTouch RF7 DUAL SPEED PLUS RF7 Dual Speed Plus 11 4 MAX 1 2 11 4 Max 8 8 10 MAX...
Страница 41: ...41...
Страница 42: ...42 MAX...
Страница 43: ...43...
Страница 44: ......
Страница 45: ...MEMO MEMORANDUM NOTIZEN NOTAS...
Страница 46: ...MEMO MEMORANDUM NOTIZEN NOTAS...