Maintenance Instructions
22.3.11
Panda_AGT-DC_5000_12V_s01285_Operation manual.R03 - Chapter 6: Maintenance Instructions Page 105
X : When No. 1 piston is at the compression top dead center position.
O : When No. 1 piston is at the overlap position.
Z482-E2B
Z602-E2B
D662-E2B
D722-E2B
D782-E2B
D902-E2B
Valve arrangement
location of piston
Number of cylin-
der
Intake valve
Exhaust valve
Intake valve
Exhaust valve
No. 1
X
X
X
X
No. 2
O
X
O
X
No. 3
-
-
X
O
Intake and exhaust valve clea-
rance (cold)
Factory spec.
0.145 to 0.185 mm
0.00571 to 0.00728 in.
NOTE
• The sequence of cylinder numbers is given as No. 1, No. 2 and No. 3 starting from the gear
case side.
• After adjusting the valve clearance, secure the adjusting screw with the lock nut.