![Fischer Panda Panda AGT 6000 Скачать руководство пользователя страница 89](http://html1.mh-extra.com/html/fischer-panda/panda-agt-6000/panda-agt-6000_manual_2294286089.webp)
Installation Instructions
9.12.14
Kapitel/Chapter 6: Installation Instructions - Seite/Page 89
Fig. 6.8.3.1-3: Tilted position 30 degrees
Tilted position 30 degrees - Fig. 6.8.3.1-3
The distance of the water level, even in ideal position, changes that only 458 mm distance remain. So the critical
distance is under-run already.
Fig. 6.8.3.1-4: Tilted position 45 degrees
Tilted position 45 degrees - Fig. 6.8.3.1-4
In this case the water level rise so high, that the distance constitutes only 325 mm.
Even when the water lock is mounted in the ideal spot, at an extremely tilted position of 45 degrees there is still the
risk that water can get straight into the discharge stack area through strong rocking motions („sloshing“). This shows
that the distance of 600 mm represents a minimum size at which, even when installed ideally, the water can slosh
into the exhaust elbow when the ship is very tilted or rocks very hard.
Содержание Panda AGT 6000
Страница 114: ...Installation Instructions Seite Page 114 Kaptitel Chapter 6 Installation Instructions 9 12 14...
Страница 150: ...Seite Page 150 Kapitel Chapter 8 Generator Failure 9 12 14 Leere Seite Intentionally blank Generator Failure...
Страница 158: ...Seite Page 158 Kapitel Chapter 9 Tables 9 12 14 Leere Seite Intentionally blank Tables...
Страница 166: ...Seite Page 166 Kapitel Chapter 10 VCS AGT U I 9 12 14 Leere Seite Intentionally blank VCS AGT U I...
Страница 190: ...Seite Page 190 Kapitel Chapter 12 Generelle Bedienung 9 12 14 Leere Seite Intentionally blank Generelle Bedienung...
Страница 192: ...Seite Page 192 Kapitel Chapter 13 Abmessungen 9 12 14 Leere Seite Intentionally blank Abmessungen...