![Fischer Panda Panda AGT 6000 Скачать руководство пользователя страница 152](http://html1.mh-extra.com/html/fischer-panda/panda-agt-6000/panda-agt-6000_manual_2294286152.webp)
Tables
Seite/Page 152 - Kaptitel/Chapter 9: Tables
9.12.14
9.1.3 Generator voltage fluctuates
9.1.4 Motor does not turn over when starting
9.1.5 Motor turns over but does not start
9.1.6 Motor does not turn over at normal speed during the start process
9.1.7 Motor runs irregularly
Cause
Solution
1. Fault or defect on the load side.
2. A motor fault.
1. Check if the power requirement of the load fluctuates.
2. See „Motor running irregularly“.
Cause
Solution
Battery main switch is switched off.
Check the position of the battery main switch, if necessary switch on.
Battery voltage not sufficient.
Check that connection is firm and whether corrosion has occurred..
Starting current fault.
The voltage of full batteries fall to a maximum of 11 V. The wiring is
severed if the voltage does not drop. The battery is discharged if the
voltage drops further.
Cause
Solution
Stop solenoid valve not opening.
Check wire connections and circuitry to solenoid valve. (ref. DC wiring
diagram: Relay K2, Fuse)
Fuel pump does not operate.
Check fuel-filter and pump: clean if necessary.
Lack of fuel.
Check fuel supply.
Glow-plugs not working correctly.
Check glow plugs and heating time.
Too much air in fuel lines.
Test fuel system for leakage. Bleed air from fuel system (refer to section
„Air-bleeding of the Fuel System“).
Fuel filter blocked.
Replace fuel filter.
Low compression pressure.
See Kubota motor-manual.
Cause
Solution
Starter battery voltage insufficient.
Check battery.
Damaged bearing(s) piston (seized).
Repairs need to be carried out by Kubota-Service. (refer to Kubota
motor-manual)
Cooling water in combustion chamber.
1. Turn generator "OFF" at control panel.
2. Remove the glow plug (see Kubota-manual).
3. Rotate the motor by hand carefully.
4. Check if there is water in the oil and change both oil and filter if
necessary.
5. Determine cause for excess water in the combustion chamber. The
excess water can be caused by a defective air vent in the cooling water
system, which should be checked and cleaned, or replaced if faulty.
Cause
Solution
Faulty centrifugal injector governor.
Have the centrifugal governor inspected by a Kubota-Service
technician.
Too much air in fuel lines.
Bleed air from fuel system.
Содержание Panda AGT 6000
Страница 114: ...Installation Instructions Seite Page 114 Kaptitel Chapter 6 Installation Instructions 9 12 14...
Страница 150: ...Seite Page 150 Kapitel Chapter 8 Generator Failure 9 12 14 Leere Seite Intentionally blank Generator Failure...
Страница 158: ...Seite Page 158 Kapitel Chapter 9 Tables 9 12 14 Leere Seite Intentionally blank Tables...
Страница 166: ...Seite Page 166 Kapitel Chapter 10 VCS AGT U I 9 12 14 Leere Seite Intentionally blank VCS AGT U I...
Страница 190: ...Seite Page 190 Kapitel Chapter 12 Generelle Bedienung 9 12 14 Leere Seite Intentionally blank Generelle Bedienung...
Страница 192: ...Seite Page 192 Kapitel Chapter 13 Abmessungen 9 12 14 Leere Seite Intentionally blank Abmessungen...