Maintenance Instructions
20.7.15
Kapitel/Chapter 7: Maintenance Instructions - Seite/Page 97
7.3
Environmental protection
Environmental protection.
Danger to the environment due to mishandling!
Significant environmental damage can occur, particularly for
incorrect disposal, if environmentally hazardous operating
materials are mishandled. Therefore:
• Always observe the instructions mentioned below.
• Take immediate action if environmentally hazardous
materials reach the environment. Inform the responsible
local authorities about the damage in the case of doubt.
The disposal must be performed by a specialist disposal company.
7.4
Maintenance Requirements
Control before starting
• Oil level
• Cooling system leaks
• Visual check for any changes, leaks oil drain system, v-belt,
cable connections, hose clips, air filter, fuel lines
Once a week
• Lubrication of actuator-trapezoid thread spindle
7.5
Maintenance interval
For the maintenance intervals, see the „General information for vehicles generators“ which are attached to this
manual.
For generators with dynamic maintenance interval (for example generators with iControl2). Further informations are
in the remote control panel manual/data sheet.
Note:
With the dynamic operation hours the service interval
can be raised up to 30% (200h max.). Make sure that the
dynamic operation hours are not reset accidently
between the service interval.
7.5.1 Check of hoses and rubber parts in the sound insulated capsule
Check all hoses and hose connections for good condition. The rubber hoses are very sensitive to environmental
influences. They wear quickly in an environment of dry air, oil and fuel vapours, and high temperatures. The hoses
must be checked regularly for elasticity. There are operating situations, when hoses must be renewed once a year.
7.6
Checking oil-level
You require:
paper towels / cloth for the oil dipstick
The generator must be placed at level.
Содержание Panda 25i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 1 20 7 15 Leere Seite Intentionally blank...
Страница 146: ...Generator Failure Seite Page 146 Kaptitel Chapter 8 Generator Failure 20 7 15...
Страница 158: ...Tables Seite Page 158 Kaptitel Chapter 9 Tables 20 7 15...
Страница 180: ...Inverter Panda PMGi 25 Seite Page 180 Kaptitel Chapter 10 Inverter Panda PMGi 25 20 7 15...
Страница 208: ...Seite Page 208 Kapitel Chapter 13 Installation 20 7 15 Leere Seite Intentionally blank Installation...
Страница 210: ...Seite Page 210 Kapitel Chapter 14 Maintenance 20 7 15 Leere Seite Intentionally blank Maintenance...
Страница 216: ...Seite Page 216 Kapitel Chapter 16 Annex 20 7 15 Leere Seite Intentionally blank Annex...