![Fischer Panda Panda 25i PMS Скачать руководство пользователя страница 214](http://html1.mh-extra.com/html/fischer-panda/panda-25i-pms/panda-25i-pms_user-manual_2294283214.webp)
Warnings and error messages
Seite/Page 214 - Kaptitel/Chapter 15: Warnings and error messages
20.7.15
15.2.3 Bus errors
If the communication connection is lost on the Fischer Panda bus, an error is output on the display after a period of
10 seconds:
Fig. 15.2.3-1: Error: „NO CONNECTION“, error in the
communication (Fischer Panda bus)
This error will occur if at least one of the two data lines
of the Fischer Panda bus is disconnected. Once the
connection is restored, the error message can be
acknowledged with the Start/Stop button.
If the communication connection is lost, the generator shall be secured (open battery disconnect switches), and all
plug-in connections and cables shall be checked for firm seating or damage.
P8-P50 marine
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
1 s
75 °C
1 s
P8-P50 vehicle
Cylinder head temperature
Delay
95 °C
5 s
100 °C
5 s
Winding temperature
Delay
160 °C
5 s
165 °C
5 s
Exhaust manifold temperature
Delay
100 °C
1 s
105 °C
1 s
P15000i marine
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
70 °C
2 s
75 °C
2 s
P15000i vehicle
Cylinder head temperature
Delay
90 °C
5 s
95 °C
5 s
Winding temperature
Delay
130 °C
5 s
135 °C
5 s
Exhaust manifold temperature
Delay
95 °C
2 s
100 °C
2 s
All generator types
Starter battery voltage low
Delay
11.8 V
30 s
10.8 V
30 s
Starter battery voltage high
15.0 V
5 s
--
--
Generator type
Warning/fault
Warning threshold
Fault threshold
Содержание Panda 25i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 1 20 7 15 Leere Seite Intentionally blank...
Страница 146: ...Generator Failure Seite Page 146 Kaptitel Chapter 8 Generator Failure 20 7 15...
Страница 158: ...Tables Seite Page 158 Kaptitel Chapter 9 Tables 20 7 15...
Страница 180: ...Inverter Panda PMGi 25 Seite Page 180 Kaptitel Chapter 10 Inverter Panda PMGi 25 20 7 15...
Страница 208: ...Seite Page 208 Kapitel Chapter 13 Installation 20 7 15 Leere Seite Intentionally blank Installation...
Страница 210: ...Seite Page 210 Kapitel Chapter 14 Maintenance 20 7 15 Leere Seite Intentionally blank Maintenance...
Страница 216: ...Seite Page 216 Kapitel Chapter 16 Annex 20 7 15 Leere Seite Intentionally blank Annex...