7.8
Verifying the starter battery and (if necessary) the battery bank
Check the condition of the battery. Proceed here as prescribed by the battery manufacturer.
If from the battery manufacturer not otherwise mentioned.
7.8.1 Battery
7.8.1.1 Check battery and cable connections
Fig. 7.8.1.1-1: Battery
• Keep battery clean and dry.
• Remove dirty clamps.
• Clean terminal posts (+ and -) and clamps of the battery,
and grease with acid-free and acid-resistant grease.
• When reassembling, ensure that clamps make good
contact. Tighten clamp bolts hand-tight.
7.8.1.2 Check electrolyte level
Fig. 7.8.1.2-1: Battery
• Remove sealing caps 1.
• If testers 2 are present:
• Electrolyte level should reach the base of these.
• Without testers:
The electrolyte level should be 10-15 mm above the top of
the plates.
• If necessary, top up with distilled water.
• Screw sealing caps back in.
Содержание Panda 25i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 1 20 7 15 Leere Seite Intentionally blank...
Страница 146: ...Generator Failure Seite Page 146 Kaptitel Chapter 8 Generator Failure 20 7 15...
Страница 158: ...Tables Seite Page 158 Kaptitel Chapter 9 Tables 20 7 15...
Страница 180: ...Inverter Panda PMGi 25 Seite Page 180 Kaptitel Chapter 10 Inverter Panda PMGi 25 20 7 15...
Страница 208: ...Seite Page 208 Kapitel Chapter 13 Installation 20 7 15 Leere Seite Intentionally blank Installation...
Страница 210: ...Seite Page 210 Kapitel Chapter 14 Maintenance 20 7 15 Leere Seite Intentionally blank Maintenance...
Страница 216: ...Seite Page 216 Kapitel Chapter 16 Annex 20 7 15 Leere Seite Intentionally blank Annex...