![Fischer Panda Panda 25i PMS Скачать руководство пользователя страница 71](http://html1.mh-extra.com/html/fischer-panda/panda-25i-pms/panda-25i-pms_user-manual_2294283071.webp)
Installation Instructions
20.7.15
Kapitel/Chapter 5: Installation Instructions - Seite/Page 71
Fig. 5.7.3.1-3: Tilted position 30 degrees
Tilted position 30 degrees - Fig. 5.7.3.1-3
The distance of the water level, even in ideal position, changes that only 458 mm distance remain. So the critical
distance is under-run already.
Fig. 5.7.3.1-4: Tilted position 45 degrees
Tilted position 45 degrees - Fig. 5.7.3.1-4
In this case the water level rise so high, that the distance constitutes only 325 mm.
Even when the water lock is mounted in the ideal spot, at an extremely tilted position of 45 degrees there is still the
risk that water can get straight into the discharge stack area through strong rocking motions („sloshing“). This shows
that the distance of 600 mm represents a minimum size at which, even when installed ideally, the water can slosh
into the exhaust elbow when the ship is very tilted or rocks very hard.
Содержание Panda 25i PMS
Страница 10: ...Seite Page 10 Kapitel Chapter 1 20 7 15 Leere Seite Intentionally blank...
Страница 146: ...Generator Failure Seite Page 146 Kaptitel Chapter 8 Generator Failure 20 7 15...
Страница 158: ...Tables Seite Page 158 Kaptitel Chapter 9 Tables 20 7 15...
Страница 180: ...Inverter Panda PMGi 25 Seite Page 180 Kaptitel Chapter 10 Inverter Panda PMGi 25 20 7 15...
Страница 208: ...Seite Page 208 Kapitel Chapter 13 Installation 20 7 15 Leere Seite Intentionally blank Installation...
Страница 210: ...Seite Page 210 Kapitel Chapter 14 Maintenance 20 7 15 Leere Seite Intentionally blank Maintenance...
Страница 216: ...Seite Page 216 Kapitel Chapter 16 Annex 20 7 15 Leere Seite Intentionally blank Annex...